IEEE Transactions on Neural Systems and Rehabilitation EngineeringBioengineeringPeer-reviewed journal article
Modeling glenohumeral stability in musculoskeletal simulations: A validation study with in vivo contact forces
Ibrahim Mohammed I. HasaniD, Italo BelliiD, Ajay SethiD, Elena M. Gutierrez-FarewikiD
Abstract
Common optimization approaches to solve the muscle redundancy problem in musculoskeletal simulations can predict shoulder contact forces that violate joint stability with lines of action outside the glenohumeral joint border. Approaches with simple joint stability constraints were previously introduced imposing an upper limit on the direction of the contact force to stay within a specified stability perimeter. Such approaches predicted higher rotator cuff muscle activation than without constraints, but the estimated joint contact forces were oriented along the specified perimeter, raising questions about validity. In this study, several glenohumeral stability formulations were investigated, and tested against in vivo measurements of glenohumeral contact forces from the Orthoload dataset on one participant data in three dumbbell tasks: lateral raise, posterior raise, and and anterior raise. The investigated formulations either imposed inequality constraints on the contact force direction to remain within a stability perimeter whose shape was varied, or added a penalty term as a criterion measure to the objective function that made the objective function costly for contact force directions to deviate from the glenoid cavity center. All stability formulations predicted contact force magnitudes that agreed relatively well to the in vivo measured forces except for the strictest formulation that constrained the joint contact force to be directed at the glenoid cavity center. Models that restricted the force direction to lie within a specified shape estimated force vectors that largely lay along the perimeters. Models that instead penalized force directions that deviated from the glenoid cavity center estimated relatively more accurate contact force directions within the glenoid cavity, though still not entirely in agreement with in vivo measurements. Our findings support the proposed penalty formulations as more reasonable and accurate than other investigated existing glenohumeral stability formulations. Author summaryIn musculoskeletal models, the glenohumeral joint is often simplified as a purely rotational joint with no translation, whereas the actual joint movement involves both rotation and some translation, requiring stabilizing forces to prevent dislocation. Models that compute muscle forces based on a minimal effort strategy without specifically addressing glenohumeral stability may underestimate co-activation of the stabilizing rotator cuff muscles, and inaccurately predict that the contact force between the humerus and the glenoid is directed outside the articular surface of the joint. In this study, we compared existing stability models and proposed a new approach that penalized joint contact force whose direction deviates from the glenoid cavity center. We integrated these approaches into a muscle redundancy solver and estimated muscle and joint forces using the thoracoscapular shoulder musculoskeletal model. We compared model estimates to in vivo measurements of joint contact forces. We found that the penalty formulation reproduced the contact force direction most accurately, and promoted greater muscle co-contraction. These findings support the proposed penalty approach as a benchmark for more accurate analysis of shoulder biomechanics using musculoskeletal simulations.
- Citations
- 2
- FWCI
- 1.87
- Field percentile
- top 13%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Does enforcing glenohumeral joint stability matter? A new rapid muscle redundancy solver highlights the importance of non-superficial shoulder muscles
Italo Belli, Sagar Joshi, … Ajay Seth·PLoS ONEPeer-reviewed·Nov 30, 2023
- Simulating the impact of glenohumeral capsulorrhaphy on movement kinematics and muscle function in activities of daily living
A. S. Fox, S. D. Gill, … R. S. Page·bioRxiv·Jun 2, 2020
- An innovative 2D-mesh model to improve deltoid moment arms, muscle forces and glenohumeral joint reaction force estimations
Marta Strzelczak, Margaux Peixoto, … Nicola Hagemeister·bioRxiv·Sep 30, 2022
- The cost of being stable: Trade-offs between effort and stability across a landscape of redundant motor solutions
M. Hongchul Sohn, Lena H. Ting·bioRxiv·Nov 22, 2018
- Functional and Structural Moment Arm Validation for Musculoskeletal Models: A Study of the Human Forearm and Hand
Matthew T. Boots, Russell L. Hardesty, … Sergiy Yakovenko·bioRxiv·May 29, 2020
- Change the direction: 3D optimal control simulation by directly tracking marker and ground reaction force data
M. Nitschke, R. Marzilger, … A. D. Koelewijn·bioRxiv·Aug 2, 2022