Magnetic Resonance in MedicineBioengineeringPeer-reviewed journal article
SMART MRS: A Simulated MEGA-PRESS Artifacts Toolbox for GABA-edited MRS
Hanna BugleriD, Amirmohammad ShamaeiiD, Roberto Medeiros de SouzaiD, Ashley D. HarrisiD
- Citations
- 2
- FWCI
- 0.95
- Field percentile
- top 30%
Abstract
PurposeTo create a Python-based toolbox to simulate commonly occurring artifacts for single voxel Gamma-Aminobutyric Acid (GABA)-edited Magnetic Resonance Spectroscopy (MRS) data. MethodsThe toolbox was designed to maximize user flexibility and contains artifact, applied, input/output (I/O), and support functions. The artifact functions can produce spurious echoes, eddy currents, nuisance peaks, line broadening, baseline contamination, linear frequency drifts, and frequency and phase shift artifacts. Applied functions combine or apply specific parameter values to produce recognizable effects such as lipid peak and motion contamination. I/O and support functions provide additional functionality to accommodate different kinds of input data (MATLAB FID-A .mat files, nifti-mrs files), which vary by domain (time vs. frequency), collection type (edited vs. non-edited) and scale. ResultsUsers may provide some or all of the required artifact function parameter values which will result in artifacts of different appearances. Visual assessment confirms the resemblance of simulated compared to in vivo produced artifacts. ConclusionOur pip installable Python artifact simulated toolbox SMART_MRS is meant to enhance the diversity and quality of existing simulated edited-MRS data and is complementary to existing MRS simulation software.
- assay: multiome
- research focus: benchmarking
- research focus: software / tool
- approach: deep learning
- approach: statistical model
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Modelling inter-shot variability for robust temporal sub-sampling of dynamic, GABA-edited MR spectroscopy data
Alexander R. Craven, Lars Ersland, … Renate Grüner·bioRxiv·Dec 5, 2024
- Comparison of seven modelling algorithms for GABA-edited 1H-MRS
Alexander R. Craven, Pallab K. Bhattacharyya, … Georg Oeltzschner·NMR in BiomedicinePeer-reviewed·Jan 25, 2022
- Advancing GABA-edited MRS Research through a Reconstruction Challenge
R. P. Berto, H. Bugler, … A. D. Harris·bioRxiv·Sep 21, 2023
- GABA-Edited Magnetic Resonance Spectroscopy Deep Learning Quality Assessment Framework
Hanna Bugler, Roberto Medeiros de Souza, Ashley D. Harris·Magnetic Resonance in MedicinePeer-reviewed·Apr 26, 2026
- Comparison of linear combination modeling strategies for GABA-edited MRS at 3T
H. J. Zöllner, S. Tapper, … G. Oeltzschner·bioRxiv·May 26, 2021
- Linewidth-related bias in modelled concentration estimates from GABA-edited 1H-MRS
Alexander R. Craven, Tiffany Bell, … Georg Oeltzschner·bioRxiv·Feb 27, 2024