bioRxivBioengineeringPreprint
MiniMAP: An automatic pipeline for paediatric lower limb musculoskeletal model generation
Laura CarmaniD, Timothy Salemink Waldren, Thor F. BesieriD, Julie ChoisneiD
Abstract
The generation of paediatric musculoskeletal models often requires compromise between data availability, accuracy, and computation time. Statistical shape models allow for rapid generation of bone geometries for use in musculoskeletal modelling. An articulated shape model allows for movement at the joints during optimisation to better fit to experimental data. Here we present a methodology for generating custom paediatric OpenSim models using an articulated shape model of the lower limb generated from CT scans of over 300 children aged 4 to 18 years old. Bone geometries are predicted using demographic factors (age, height, mass, and sex), linear bone measurements (bone widths and lengths), and 12 skin surface landmarks (L/R ASIS, L/R PSIS, medial/lateral epicondyles, and medial/lateral malleoli). To account for skin padding (bone to skin surface distance) a random forest algorithm was developed for skin padding prediction for these 12 landmarks. Accuracy of the model prediction was assessed using a leave-one-out analysis to assess landmark errors, bone surface errors, and clinical bone measurement errors (linear measurements and angular values). Motion capture and MRI data were collected from two paediatric test cases to test the workflow on unseen data. Skin padding values varied widely in this population with average values from 3.4mm at the lateral malleolus to 25.9mm at the PSIS. Skin padding was best predicted using age, height, mass, ASIS width, epicondylar width, and malleolar width with an average RMSE of 4.68mm. The articulated shape model predicted accurate bone geometries from skin surface landmarks with average bone surface RMSEs of 2.64 {+/-} 0.99mm, 1.91 {+/-} 0.59mm, and 1.69 {+/-} 0.56mm in the pelvis, femora, and tibiae/fibulae respectively. In the two unseen test cases, average bone surface errors ranged from 1.64 {+/-} 1.2mm to 3.41 {+/-} 3.1mm. This study demonstrated the accuracy of "MiniMAP", for the rapid generation of custom paediatric musculoskeletal models.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Automatic Generation of Personalised Skeletal Models of the Lower Limb from Three-Dimensional Bone Geometries
L. Modenese, J.-B. Renault·bioRxiv·Jun 23, 2020
- Minimal medical imaging can accurately reconstruct geometric bone models for musculoskeletal models
E. Suwarganda, L. Diamond, … T. Savage·bioRxiv·Oct 1, 2018
- A Workflow to Create Personalised Musculoskeletal Models Based on Magnetic Resonance Images
Ekaterina Stansfield, Willi Koller, … Hans Kainz·bioRxiv·Jul 23, 2025
- Femoral bone growth predictions based on personalized multi-scale simulations: Validation and sensitivity analysis of a mechanobiological model
Willi Koller, Martin Švehlík, … Hans Kainz·Biomechanics and Modeling in MechanobiologyPeer-reviewed·Apr 14, 2025
- MSK-Morph: An automated framework to systematically morph landmark-defined musculoskeletal models into subject-specific bone geometries
Judit Cueto Fernandez, Christal van de Steeg‐Henzen, … Eline van der Kruk·bioRxiv·May 12, 2026
- Development and evaluation of a new methodology for Soft Tissue Artifact compensation in the lower limb
B. K. Lahkar, P.-Y. Rohan, … W. Skalli·bioRxiv·Feb 8, 2021