Agreement between Garmin and Ultrahuman wearables and their association with continuous glucose monitoring: an n-of-1 study
Abstract
Background: Consumer wearables and continuous glucose monitors (CGM) are increasingly worn together outside clinical settings. Few studies have examined whether two wearables worn at the same time agree with each other, and whether either tracks glucose metrics derived from CGM. Objective: In one adult under free-living conditions, we examined (1) how well sleep, heart rate, heart rate variability (HRV) and activity metrics from a Garmin smartwatch and an Ultrahuman ring agreed with each other, and (2) how these metrics related to glucose measured by CGM. Methods: One healthy adult with no diagnosed diabetes wore a Garmin Fenix 8 watch on the wrist, an Ultrahuman Ring AIR and an Abbott FreeStyle Libre CGM at the same time for 12 days (29 July to 9 August 2026; 1101 glucose readings). We assessed agreement between the devices with Pearson correlation and Bland-Altman analysis (mean bias and 95% limits of agreement, LoA) for daily metrics and for heart rate within the day, and with Cohen's kappa for sleep stages, minute by minute. We related the wearable metrics to mean glucose, glucose variability (coefficient of variation, CV%) and time in range (TIR, 3.9 to 10.0 mmol/L), reading by reading (over the whole record and separately for sleep and waking hours) and day by day. All correlations are descriptive. Because the Ultrahuman ring recorded no data for 22 hours on 3 August and its daytime heart rate behaved differently afterwards, heart-rate analyses are reported for the whole period and separately before and after that gap. The daily results were checked by leaving out one day at a time and by excluding the first 24 hours of sensor wear. Results: The devices agreed closely on total sleep duration (r=0.94; bias -0.02 h, 95% LoA -0.56 to 0.51 h). Daily steps correlated strongly (r=0.99 over the 11 days with data from both devices), but Garmin counted more steps on every day (mean 11,157 vs. 8,929 steps per day; bias +2228 steps). Heart rate agreed moderately during sleep (r=0.68). While awake, agreement was moderate before the gap (r=0.54) and absent after it (r=0.08), when Ultrahuman's daytime heart rate stayed near 70 bpm. The devices assigned the same sleep stage in 50.0% of 4525 minutes (kappa=0.28). Mean glucose was 5.13 mmol/L (SD 0.82) and TIR was 97.5%. Of all wearable signals, heart rate was most closely associated with glucose (Garmin r=0.43 over all readings), but the correlation fell to 0.34 within sleep and 0.21 within waking hours, and before the gap the two devices' waking correlations were alike (Garmin 0.25, Ultrahuman 0.24). Across the 12 days, correlations between night-time wearable metrics and glucose variability weakened markedly when the first 24 hours of sensor wear were excluded (absolute r fell from 0.59 or more to 0.34 or less), and TIR was 100% on 8 of the 12 days, which left it little room to vary. Conclusions: The two wearables agreed on how long the participant slept but not on how the night was staged, and their heart-rate agreement depended on whether the participant was asleep or awake and on the period of wear. Of all wearable signals, heart rate was most closely associated with glucose, mainly because both are lower at night and higher during the day. The associations across days rested largely on the first night of sensor wear. In this single participant, the devices behaved differently by device and by period of wear, so studies that combine different wearables, or relate them to CGM, should check for such differences before pooling data.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Accuracy in wrist-worn, sensor-based measurements of heart rate and energy expenditure in a diverse cohort
Anna Shcherbina, C. Mikael Mattsson, … Euan Angus Ashley·Journal of Personalized MedicinePeer-reviewed·May 24, 2017
- SGCI (Smartwatch Gait Coordination Index): New Measure for Human Gait Utilizing Smartwatch Sensor
- Smartwatch-based prediction of single-stride and stride-to-stride gait outcomes using regression-based machine learning
C. A. Bailey, A. Mir-Orefice, … R. B. Graham·bioRxiv·Jan 30, 2023
- R Functions for Analysis of Continuous Glucose Monitor Data
Tim Vigers, Christine L. Chan, … Laura L. Pyle·PLoS ONEPeer-reviewed·Oct 11, 2019
- Edge-First Ground Reaction Force Estimation with Consumer Smartwatches
Parvin Ghaffarzadeh, Debarati Chakraborty, … Yiannis Papadopoulos·IEEE Internet ComputingPeer-reviewed·Jan 1, 2026
- Validity of Optical Heart Rate Measurement in Commercially Available Wearable Fitness Tracking Devices