Ultrasound in Medicine & BiologyBioengineeringPeer-reviewed journal article
HipSAFE: automating hip fracture detection on ultrasound imaging using deep learning
Nicholas J. YeeiD, Yohannes SoenjayaiD, Noah Kates RoseiD, Angela AtingaiD, Christine E. M. DemoreiD, Mansur M. HalaiiD, Cari WhyneiD, Michael HardistyiD
Abstract
Falls among older adults can result in hip fractures that requires x-ray based assessment at emergency department (ED). Only 25.7% of patients presenting to EDs are diagnosed with a hip fracture, as such improved diagnosis prior to transportation to hospital could result in fewer hospital visits and improved triaging. Patient with hip fracture could be immediately directed to centres with orthopaedic surgeons, allowing for reduced time-to-surgery, particularly in rural communities. Ultrasound (US) imaging is portable and can identify fractures but requires expertise, particularly related to image interpretation. Deep learning may reduce operator dependence by automating image interpretation. This study aims to develop HipSAFE, a hip fracture detection tool on US, to support triaging by nurses and paramedics. We hypothesize that diagnostic accuracy will be comparable to pelvic x-ray diagnostic performance in a preclinical study. Bilateral hind limbs of 15 porcine cadavers were imaged by US-naive operators before and after an iatrogenic hip fracture. The limbs were divided into training, validation, and test (8 femurs) sets. The training data were augmented (geometric and photometric transformations). The models included MobileNetV3 (S/L), EfficientNet-Lite (0-2), and ResNet (18/50). Using a moving average aggregation on the operator cine clips, EfficientNet-Lite0 achieved the highest performance (F1=0.944 [95% CI:0.880-0.987]; sensitivity=89.5% [78.6-97.5%]; specificity = 100.0% [100.0-100.0]). The majority voting ensemble model ranked second (F1=0.932 [0.857-0.984]). Naive operators and radiologists had lower performance (F1=0.667 [0.596-0.758] and 0.685 [0.597-0.729]). This pre-clinical study demonstrated that HipSAFE has excellent diagnostic accuracy and there may be a role for US in improving hip trauma triaging, especially for rural and resource-constrained environments.
- Citations
- 0
- FWCI
- 0.00
- Field percentile
- 10th percentile
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- CNN-based radiographic acute tibial fracture detection in the setting of open growth plates
Zbigniew A Starosolski, Herman Kan, Ananth Annapragada·bioRxiv·Jan 3, 2019
- A deep learning classification task for brain navigation during functional ultrasound imaging
Théo Lambert, Clément Brunner, … Alan Urban·HeliyonPeer-reviewed·Mar 1, 2024
- Deep learning-based segmentation of high-resolution computed tomography image data outperforms commonly used automatic bone segmentation methods
D. M. Patton, E. N. Henning, … T. L. Bredbenner·bioRxiv·Jul 27, 2021
- Deep-fUS: functional ultrasound imaging of the brain using deep learning and sparse data
T. Di Ianni, R. Airan·bioRxiv·Sep 29, 2020
- Feasibility of Automated Deep Learning Design for Medical Image Classification by Healthcare Professionals with Limited Coding Experience
Livia Faes, Siegfried K. Wagner, … Pearse Andrew Keane·bioRxiv·May 27, 2019
- Modeling Combined Ultrasound and Photoacoustic Imaging: Simulations aiding Device Development and Deep Learning
S. Agrawal, A. Dangi, S.-R. Kothapalli·bioRxiv·Nov 7, 2020