bioRxivPhysiology
Accuracy of a battery-powered portable capnometer in neonates
Abstract
End-tidal CO2 measurement (EtCO2) is useful for confirmation of successful tracheal intubation and ensuring adequate ventilation. There are two types of EtCO2 detector, i.e., single-use-only devices and capnometers. Although portable capnometers are widely used for resuscitation, there have been no reports regarding their clinical utility in neonates. Here, the correspondence between EtCO2 level determined using a battery-powered portable capnometer and arterial CO2 (PaCO2) was investigated using paired data obtained simultaneously from 26 neonates weighing 1262 ± 589 g at examination on mechanical ventilation. EtCO2 level and PaCO2 showed a strong correlation (r = 0.839, P < 0.001), and the correlation equation was: EtCO2 = 0.8 × PaCO2 + 1.1. Therefore, EtCO2 readings obtained with a battery-powered portable capnometer were likely to be underestimated. This became more pronounced with decreasing infant body weight at examination as the net difference in measurements of PaCO2 and EtCO2 was significantly positively correlated with infant body weight at examination (r = 0.451, P < 0.001). The observations presented here may be helpful in the use of battery-powered portable capnometers in neonates requiring controlled ventilation with tracheal intubation.View Full Text
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Maternal arterial blood values during delivery: effect of mode of delivery, maternal characteristics, obstetric interventions and correlation to fetal umbilical cord blood
M. Zaigham, S. Helfer, … N. Wiberg·bioRxiv·Feb 14, 2020
- Cortical motor activity modulates respiration and reduces apnoea in neonates
Coen S. Zandvoort, Fatima Usman, … Caroline Hartley·eLifePeer-reviewed·May 12, 2026
- Arterial carboxyhaemoglobin levels in children admitted to PICU: a retrospective observational study
- Acute buprenorphine exposure depresses neonatal respiratory chemoreflexes in the presence or absence of naloxone
Michael L. Frazure, Khushi Praveen, … Ralph Frank Fregosi·bioRxiv·May 17, 2026
- Aeration Strategy at Birth Does Not Impact Carotid Blood Flow and Oxygen Delivery in Preterm Lambs
- Adapting Indirect Calorimetry to measure metabolic status of healthy and septic neonatal mice
Adrien Eynaud, J. P. Solomon, … Nelly Amenyogbe·Scientific ReportsPeer-reviewed·Aug 25, 2026