bioRxivNeuroscience
Eye-movement artifact correction in infant EEG
Diksha Srishyla, Sara Jane WebbiD, Mayada ElsabbaghiD, Christian O’ReillyiD
Abstract
BackgroundIndependent Component Analysis (ICA) is a well-established approach to clean EEG and remove the impact of signals of non-neural origin, such as those from muscular activity and eye movements. However, evidence suggests that ICA removes artifacts less effectively in infants than in adults. This study systematically compares ICA and Artifact Blocking (AB), an alternative approach proposed to improve eye-movement artifact correction in infant EEG. MethodsWe analyzed EEG collected from 50 infants between 6 and 18 months of age as part of the International Infant EEG Data Integration Platform (EEG-IP), a longitudinal multi-study dataset. EEG was recorded while infants sat on their caregivers laps and watched videos. We used ICA and AB to correct for eye-movement artifacts in the EEG and calculated the proportion of effectively corrected segments, signal-to-noise ratio (SNR), power-spectral density (PSD), and multiscale entropy (MSE) in manually selected EEG segments with and without eye-movement artifacts. ResultsOn the one hand, the proportion of effectively corrected segments indicated that ICA corrected eye-movement artifacts (sensitivity) better than AB. SNR and PSD indicated that both AB and ICA correct eye-movement artifacts with equal sensitivity. MSE gave mixed results. On the other hand, AB caused less distortion to the clean segments (specificity) for SNR, PSD, and MSE. ConclusionsOur results suggest that ICA is more sensitive (i.e., it better removes artifacts) but less specific (it distorts clean signals) than AB for correcting eye-movement artifacts in infant EEG.
- organism: human
- assay: electronic health records
- research focus: batch correction / integration
- approach: statistical model
- Citations
- 4
- FWCI
- 2.27
- Field percentile
- top 13%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Automatic classification of ICA components from infant EEG using MARA
Ira Marriott Haresign, Emily Phillips, … Sam V. Wass·Developmental Cognitive NeurosciencePeer-reviewed·Oct 22, 2021
- Optimized ICA-based removal of ocular EEG artifacts from free viewing experiments
Olaf Dimigen, Humboldt-Universität zu Berlin·NeuroImagePeer-reviewed·Nov 3, 2019
- Topographical and spectral signatures of infant and adult movement artifacts in naturalistic EEG
Stanimira Georgieva, Suzannah Lester, … Victoria Leongi·bioRxiv·Jul 18, 2018
- Combining eye tracking with EEG: Effects of filter settings on EEG for trials containing task relevant eye-movements
Louisa Kulke, Vincent Kulke·bioRxiv·Apr 22, 2020
- State-of-the-art EEG artifact removal evaluation
Zhenyu Jin·bioRxiv·Oct 23, 2021
- Identifying key factors for improving ICA-based decomposition of EEG data in mobile and stationary experiments
Marius Klug, Klaus Gramann·European Journal of NeurosciencePeer-reviewed·Oct 4, 2020