Magnetic Resonance in MedicineNeurosciencePeer-reviewed journal article
Denoising complex-valued diffusion MR images using a two-step non-local principal component analysis approach
Xinyu YeiD, Xiaodong MaiD, Ziyi PaniD, Zhe ZhangiD, Hua GuoiD, Kǎmil UǧurbiliD, Xiaoping WuiD
Abstract
Purposeto propose a two-step non-local principal component analysis (PCA) method and demonstrate its utility for denoising diffusion tensor MRI (DTI) with a few diffusion directions. MethodsA two-step denoising pipeline was implemented to ensure accurate patch selection even with high noise levels and was coupled with data preprocessing for g-factor normalization and phase stabilization before data denoising with a non-local PCA algorithm. At the heart of our proposed pipeline was the use of a data-driven optimal shrinkage algorithm to manipulate the singular values in a way that would optimally estimate the noise-free signal. Our approachs denoising performances were evaluated using simulation and in-vivo human data experiments. The results were compared to those obtained with existing local-PCA-based methods. ResultsIn both simulation and human data experiments, our approach substantially enhanced image quality relative to the noisy counterpart, yielding improved performances for estimation of relevant DTI metrics. It also outperformed existing local-PCA-based methods in reducing noise while preserving anatomic details. It also led to improved whole-brain tractography relative to the noisy counterpart. ConclusionThe proposed denoising method has the utility for improving image quality for DTI with reduced diffusion directions and is believed to benefit many applications especially those aiming to achieve quality parametric mapping using only a few image volumes.
- Citations
- 5
- FWCI
- 1.76
- Field percentile
- top 16%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Denoising High-field Multi-dimensional MRI with Local Complex PCA
Pierre‐Louis Bazin, Anneke Alkemade, … Birte U. Forstmann·Frontiers in NeurosciencePeer-reviewed·Oct 9, 2019
- NOise Reduction with DIstribution Corrected (NORDIC) PCA in dMRI with complex-valued parameter-free locally low-rank processing
Steen Moeller, Pramod Kumar Pisharady, … Mehmet Akçakaya·NeuroImagePeer-reviewed·Nov 10, 2020
- Efficient PCA denoising of spatially correlated MRI data
Rafael Neto Henriques, Andrada Ianuș, … Noam Shemesh·bioRxiv·Mar 29, 2023
- Denoising Diffusion MRI: Considerations and implications for analysis
J.P Manzano-Patron, Steen Moeller, … Stamatios N. Sotiropoulos·Imaging NeurosciencePeer-reviewed·Dec 14, 2023
- Offline Reconstruction of Diffusion MRI Acquisitions for Comparison Between Complex PCA-based and AI-based Denoising
Francesco D'Antonio, Shaun Warrington, … Stamatios N. Sotiropoulos·Magnetic Resonance in MedicinePeer-reviewed·Mar 7, 2026
- Denoising diffusion weighted imaging data using convolutional neural networks
Hu Cheng, Sophia Vinci‐Booher, … Franco Pestilli·PLoS ONEPeer-reviewed·Sep 15, 2022