Sign in
NeuroscienceMagnetic Resonance in Medicine
Peer-reviewed journal article

Offline Reconstruction of Diffusion MRI Acquisitions for Comparison Between Complex PCA-based and AI-based Denoising

Francesco D'AntonioiD, Shaun WarringtoniD, J.P Manzano-PatroniD, Paul S. MorganiD, Stamatios N. SotiropoulosiD

Abstract

PurposeOptimal diffusion MRI (dMRI) data for image denoising is often unavailable from scanner reconstruction. In this work, we make available an offline reconstruction pipeline for GE dMRI acquisitions, giving access to complex dMRI data. Furthermore, we compare the efficacy of GE HealthCares AIR-Recon DL (ARDL), a proprietary convolutional neural network-based reconstruction and denoising approach, to open-source PCA-based MPPCASVS and NORDIC denoising methods on high-resolution dMRI data. MethodsWe developed an end-to-end offline dMRI reconstruction pipeline for GE HealthCare acquisitions, augmenting the Orchestra software development kit, and validated its output against scanner reconstruction. We used it to compare MPPCASVS, NORDIC and ARDL denoising approaches, considering underlying metrics reflecting noise variance and bias, such as the ADC profiles in highly anisotropic areas, and downstream measurements, such as fiber orientation estimation and white matter tractography. ResultsOur validated offline reconstruction supports various in-plane/out-of-plane accelerations and partial Fourier reconstruction methods. Unlike scanner reconstruction, it provides access to complex dMRI data, enabling denoising in the complex domain, which demonstrated superior noise floor suppression compared to magnitude-constrained denoising. PCA-based denoising methods had improved spatial resolution, contrast-to-noise and more robust fiber orientation estimation compared to ARDL. ConclusionWe found significant gains in dMRI data quality when using the proposed offline reconstruction pipeline, allowing complex-domain denoising to obtain high-quality data at high spatial resolution and b-value, using a wide-bore scanner and a standard PGSE EPI sequence. MPPCASVS and NORDIC (4D PCA-based) outperformed ARDL (2D) in terms of spatial resolution, reduction of noise-floor bias and variance.

PDFDOI

02 /Specification & Classification

Click any tag to browse matching papers

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISMoeller '20Manzano-Pat '23Ye '25Bazin '19Henriques '23Li '21
77% semantic matchNeuroscience
Steen Moeller, Pramod Kumar Pisharady, Sudhir Ramanna+6 more·NeuroImage·Nov 10, 2020· 147 citations