Abstract
PurposeOptimal diffusion MRI (dMRI) data for image denoising is often unavailable from scanner reconstruction. In this work, we make available an offline reconstruction pipeline for GE dMRI acquisitions, giving access to complex dMRI data. Furthermore, we compare the efficacy of GE HealthCares AIR-Recon DL (ARDL), a proprietary convolutional neural network-based reconstruction and denoising approach, to open-source PCA-based MPPCASVS and NORDIC denoising methods on high-resolution dMRI data. MethodsWe developed an end-to-end offline dMRI reconstruction pipeline for GE HealthCare acquisitions, augmenting the Orchestra software development kit, and validated its output against scanner reconstruction. We used it to compare MPPCASVS, NORDIC and ARDL denoising approaches, considering underlying metrics reflecting noise variance and bias, such as the ADC profiles in highly anisotropic areas, and downstream measurements, such as fiber orientation estimation and white matter tractography. ResultsOur validated offline reconstruction supports various in-plane/out-of-plane accelerations and partial Fourier reconstruction methods. Unlike scanner reconstruction, it provides access to complex dMRI data, enabling denoising in the complex domain, which demonstrated superior noise floor suppression compared to magnitude-constrained denoising. PCA-based denoising methods had improved spatial resolution, contrast-to-noise and more robust fiber orientation estimation compared to ARDL. ConclusionWe found significant gains in dMRI data quality when using the proposed offline reconstruction pipeline, allowing complex-domain denoising to obtain high-quality data at high spatial resolution and b-value, using a wide-bore scanner and a standard PGSE EPI sequence. MPPCASVS and NORDIC (4D PCA-based) outperformed ARDL (2D) in terms of spatial resolution, reduction of noise-floor bias and variance.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 1
- FWCI
- 4.67
- Field percentile
- top 9%
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- NOise Reduction with DIstribution Corrected (NORDIC) PCA in dMRI with complex-valued parameter-free locally low-rank processing
Steen Moeller, Pramod Kumar Pisharady, … Mehmet Akçakaya·NeuroImagePeer-reviewed·Nov 10, 2020
- Denoising Diffusion MRI: Considerations and implications for analysis
J.P Manzano-Patron, Steen Moeller, … Stamatios N. Sotiropoulos·Imaging NeurosciencePeer-reviewed·Dec 14, 2023
- Denoising complex-valued diffusion MR images using a two-step non-local principal component analysis approach
Xinyu Ye, Xiaodong Ma, … Xiaoping Wu·Magnetic Resonance in MedicinePeer-reviewed·Mar 13, 2025
- Denoising High-field Multi-dimensional MRI with Local Complex PCA
Pierre‐Louis Bazin, Anneke Alkemade, … Birte U. Forstmann·Frontiers in NeurosciencePeer-reviewed·Oct 9, 2019
- Efficient PCA denoising of spatially correlated MRI data
Rafael Neto Henriques, Andrada Ianuș, … Noam Shemesh·bioRxiv·Mar 29, 2023
- High-fidelity fast volumetric brain MRI using synergistic wave-controlled aliasing in parallel imaging and a hybrid denoising generative adversarial network
Ziyu Li, Qiyuan Tian, … Susie Y. Huang·Medical PhysicsPeer-reviewed·Dec 28, 2021