PurposeTo evaluate methods for quantification of pulmonary ventilation with ultrashort echo time (UTE) MRI. MethodsWe performed a reproducibility study, acquiring two free-breathing 1H UTE lung MRIs on the same day for six healthy volunteers. The 1) 3D + t cyclic b-spline and 2) symmetric image normalization (SyN) methods for image registration were applied after respiratory phase-resolved image reconstruction. Ventilation maps were calculated using 1) Jacobian determinant of the deformation fields minus one, termed regional ventilation, and 2) intensity percentage difference between the registered and fixed image, termed specific ventilation. We compared the reproducibility of all four method combinations via statistical analysis. ResultsSplit violin plots and Bland-Altman plots are shown for whole lungs and lung sections. The cyclic b-spline registration and Jacobian determinant regional ventilation quantification provide total ventilation volumes that match the segmentation tidal volume, smooth and uniform ventilation maps. The cyclic b-spline registration and specific ventilation combination yields the smallest standard deviation in the Bland-Altman plot. ConclusionCyclic registration performs better than SyN for respiratory phase-resolved 1H UTE MRI ventilation quantification. Regional ventilation correlates better with segmentation lung volume, while specific ventilation is more reproducible.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Characteristics of respiratory measures in young adults scanned at rest, including systematic changes and \"missed\" respiratory events
Jonathan D. Power, Benjamin Silver, … Rebecca Merrill Jones·bioRxiv·Apr 18, 2019
- A Hilbert-based method for processing respiratory timeseries
Samuel J. Harrison, Samuel Bianchi, … Lars Kasper·NeuroImagePeer-reviewed·Jan 28, 2021
- Dynamic oxygen-enhanced MRI of the lung at 3 T: feasibility, repeatability and reproducibility
M. Kim, J. H. Naish, … G. J. M. Parker·bioRxiv·Apr 9, 2023
- Quantitative mapping of cerebrovascular reactivity amplitude and delay with breath-hold BOLD fMRI when end-tidal CO2 quality is low
Rebecca G. Clements, Kristina M. Zvolanek, … Molly G. Bright·Imaging NeurosciencePeer-reviewed·Jan 1, 2025
- Comparing end-tidal CO2, respiration volume per time (RVT), and average gray matter signal for mapping cerebrovascular reactivity amplitude and delay with breath-hold task BOLD fMRI
Kristina M. Zvolanek, Stefano Moia, … Molly G. Bright·NeuroImagePeer-reviewed·Mar 22, 2023
- Evaluation of MRI sequences for quantitative T1 brain mapping
P. Tsialios, M. Thrippleton, C. Pernet·bioRxiv·Sep 29, 2017