Low-Latency sEMG Conditioning with Frequency-Tracked Harmonic PLI Cancellation and Exponential RMS Envelope Estimation

Hong U Lo, Zibo Gao, Hoi Fong Loi, Sok Kin Cheng

Abstract

Surface electromyography (sEMG) interfaces require interference-resistant acquisition, faithful preprocessing, and a responsive envelope for downstream control. This work presents a reproducible, analog-aware digital conditioning pipeline comprising an eighth-order Butterworth band-pass, a narrow static notch, a recursive-oscillator two-harmonic normalised least-mean-squares (NLMS) canceller, a rolling mains-frequency tracker, and an exponentially weighted RMS (EMRMS) envelope. The analog common-mode analysis is separated into a complex frequency-domain decomposition and a scalar CMRR sensitivity screen; the latter is explicitly treated as a pre-prototype approximation rather than a substitute for circuit simulation or bench measurement. A running-sum rectangular RMS requires O(1) arithmetic and O(L) memory, whereas EMRMS requires O(1) arithmetic and one dynamic power state. At fs = 2 kHz and{tau} = 25 ms, the EMRMS power smoother has a weight-centroid delay of 24.75 ms and a noise-equivalent rectangular length of 100.0 samples. In a controlled drifting-line experiment, the tracker achieved an RMSE of 0.118 Hz; tracked two-harmonic cancellation improved whole-record reconstruction SNR by approximately 19.3 dB relative to the static-notch baseline. In a separate 12-channel synthetic ablation, median reconstruction SNR was 11.5 dB for tracked harmonic cancellation, compared with 8.8 dB for fixed-frequency harmonic cancellation and -11.2 dB for the static-notch baseline. Delay-aligned EMRMS and length-200 running-RMS envelopes had correlation{rho} = 0.994. The host-Python fast path required a median of 13.0 {micro}s per sample and a 99th percentile of 24.9 {micro}s; accepted frequency updates required a median of 161 {micro}s and should be scheduled as a supervisory task on embedded hardware. All numerical performance results reported here are controlled synthetic experiments. The accompanying real-data workflow never substitutes generated data when recordings are absent; multi-subject and embedded-hardware validation remain future work.

PDFDOI

02 /Specification & Classification

Click any tag to browse matching papers

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.