henhaobio
Sign in

Biophotonics discovery.BioengineeringPeer-reviewed journal article

Evaluation of a Polarization-Sensitive, Dual-Wavelength Wearable Photoplethysmography Sensor Across a Range of Skin Tones

Rutendo JakachiraiD, Wenyuan YaniD, Sian C. Thomas, Yareli Macias-Sanchez, Lovisa Werner, Joshua A. BurrowiD, SHIRA I. DUNSIGERiD, Kimani C. ToussaintiD

PDFDOIPreprint

Abstract

SignificanceHigh-quality photoplethysmography (PPG) signals are essential for accurate extraction of cardiovascular metrics such as heart rate, heart rate variability, and perfusion index. However, signal degradation for individuals with dark skin tones can compromise PPG quality and pose challenges for equitable sensing. AimWe develop a dual-wavelength, polarization-sensitive PPG device to assess perfusion index (PI) across a range of skin tones. ApproachTo evaluate the impact of polarization on PPG signal quality, we record PI for co-polarized (polarized illumination and parallel-aligned polarized detection), and cross-polarized conditions (polarized illumination and orthogonally aligned polarized detection) at 655 nm and 940 nm in participants representing light, medium, and brown skin tone categories. Skin tone classification are based on the individual typology angle (ITA) values derived from the CIE L*b* color space measurements. ResultsAt 940 nm, light from the cross-polarized light channel significantly increases PI (p < 0.05). At 655 nm, cross-polarization presents a statistically significantly enhanced PI (p < 0.05) relative to light from the co-polarized illumination condition, although the magnitude of the improvement decreases with lighter skin tone indication a possible interaction between skin tone and polarization. This improvement is consistent across all skin tones. ConclusionsOur results suggest that the cross-polarized condition improves PPG signal quality by reducing the influence of superficial scattering and enhancing deeper vascular signals. This approach may be especially beneficial for individuals with darker skin tones and offers a promising path towards more robust and inclusive physiological monitoring using PPG-based technologies.

Citations
2
FWCI
0.49
Field percentile
top 42%

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISBoonya-Anan '20Jung '26Lacerenza '24Else '23Jung '26Cabal '25
63% semantic matchBioengineering
T. Boonya-Ananta, A. J. Rodriguez, A. Ajmal+3 more·bioRxiv·Jul 22, 2020