Human Brain MappingNeurosciencePeer-reviewed journal article
Measuring brain beats: cardiac-aligned fast fMRI signals
Dora HermesiD, Hua WuiD, Adam B. KerriD, Brian Arie WandelliD
Abstract
Blood and cerebrospinal fluid (CSF) pulse and flow throughout the brain, driven by the cardiac cycle. These fluid dynamics, which are essential to healthy brain function, are characterized by several noninvasive magnetic resonance imaging (MRI) methods. Recent developments in fast MRI, specifically simultaneous multislice (SMS) acquisition methods, provide a new opportunity to rapidly and broadly assess cardiac-driven flow, including CSF spaces, surface vessels and parenchymal vessels. We use these techniques to assess blood and CSF flow dynamics in brief (3.5 minute) scans on a conventional 3T MRI scanner. Cardiac pulses are measured with a photoplethysmograph (PPG) on the index finger, along with fMRI signals in the brain. We retrospectively analyze the fMRI signals gated to the heart beat. Highly reliable cardiac-gated fMRI temporal signals are observed in CSF and blood on the timescale of one heartbeat (test-retest reliability within subjects R2>0.50). Cardiac pulsations with a local minimum following systole are observed in blood vessels, with earlier extrema in the carotid and basilar arteries and in branches of the anterior, posterior and middle cerebral arteries and extrema [~]200 ms later in the superior sagittal, transverse and straight sinuses. CSF spaces in the ventricles and subarachnoid space showed cardiac pulsations with a local maximum following systole instead. Similar responses are observed, with less temporal detail, in slower resting state scans with slice timing retrospectively aligned to the cardiac pulse in the same manner. The SMS measurements rapidly, noninvasively and reliably sample brain-wide fMRI signal pulsations aligned to the heartbeat. The measurements estimate the amplitude and phase of cardiac driven fMRI pulsations in the CSF relative to those in the arteries, which is thought to be an estimate of the local intracranial impedance. Cardiac aligned fMRI signals can provide new insights about fluid dynamics or diagnostics for diseases where these dynamics are important.
- Citations
- 17
- FWCI
- 1.85
- Field percentile
- top 15%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Quantifying brain-wide cerebrospinal fluid flow dynamics using slow-flow-sensitized phase-contrast MRI
Zijing Dong, Fuyixue Wang, … Jon̈athan R. Polimeni·bioRxiv·Mar 22, 2025
- Quantifying cardiac, respiratory, and slow vasomotion components of CSF motion from fMRI inflow effects
Pontus Söderström, Cecilia Björnfot, … Anders Wåhlin·Magnetic Resonance in MedicinePeer-reviewed·May 17, 2026
- Vascular origins of low-frequency oscillations in the cerebrospinal fluid signal in resting-state fMRI: Interpretation using photoplethysmography
A. Attarpour, J. Ward, J. J. Chen·bioRxiv·Oct 2, 2020
- Ultrafast fMRI detects age-related changes in harmonics of cardiac pulsations in the brain at 7 T
Charles Marchini, Dema Abdelkarim, … Bradley P. Sutton·Magnetic Resonance in MedicinePeer-reviewed·May 10, 2026
- Simultaneous Real-time Imaging of Neurofluid and Neurovascular Dynamics Using Ultrafast Flow-weighted Echo-Planar Imaging
Amir H. Shaker, Amir HG. Arani, … Arash Nazeri·bioRxiv·Jan 16, 2026
- Cardiovascular and vasomotor pulsations in the brain and periphery during awake and NREM sleep in a multimodal fMRI study
Johanna Tuunanen, Heta Helakari, … Vesa O. Korhonen·Frontiers in NeurosciencePeer-reviewed·Oct 8, 2024