Journal of Proteome ResearchBioinformaticsPeer-reviewed journal article
How much storage precision can be lost: Guidance for near-lossless compression of untargeted metabolomics mass spectrometry data
Junjie TongiD, Miaoshan LuiD, Ruimin WangiD, Shaowei AniD, Jinyin WangiD, Tong WangiD, Cong XieiD, Changbin Brad YuiD
Abstract
The size of high-resolution mass spectrometry (HRMS) data has been increasing significantly. Several lossy compressors have been developed for higher compression rates. Currently, a comprehensive evaluation of what and how MS data (m/z and intensities) with precision losses would affect data processing (i.e., feature detection and compound identification) is absent. Here, we set an error threshold at 1% to assess the significance of the difference between two files in feature and compound detection results obtained from MZmine3. First, we examined that mzML files with both m/z and intensity encoded in 32-bit precision appear to be a preferred combination via msConvert, which has smaller file size and minor variation with other combinations of storage precision (<0.13%). We then identified that the absolute error of 10-4 for m/z had a feature detection error of 0.57% and compound detection error of 1.1%. For intensities, the relative error group of 2x10-2 had an error of 4.65% for features and 0.98% for compounds, compared with precision-lossless files. Taken together, we provided a reasonable scene-accuracy proposal, with a maximum absolute error of 10-4 for m/z and a maximum relative error of 2x10-2 for intensity. This guidance aimed to help researchers in improving lossy compression algorithms and minimizing the negative effects of precision losses on downstream data processing.
- assay: metabolomics
- research focus: benchmarking
- research focus: variant effect prediction
- approach: statistical model
- Citations
- 7
- FWCI
- 0.68
- Field percentile
- top 38%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- MassComp, a lossless compressor for mass spectrometry data
Ruochen Yang, Xi Chen, Idoia Ochoa·BMC BioinformaticsPeer-reviewed·Jul 1, 2019
- Aird: A computation-oriented mass spectrometry data format enables higher compression ratio and less decoding time
Miaoshan Lu, Shaowei An, … Changbin Brad Yu·bioRxiv·Oct 14, 2020
- A Multiresolution Hierarchical Approach to Peak Picking for High Resolution Mass Spectrometry Data Analysis
Vojtěch Bartoň, Ivana Ihnatová, … Vlad Popovici·bioRxiv·Dec 10, 2025
- Aird-ComboComp: A combinable compressor framework with a dynamic-decider for lossy mass spectrometry data compression
Miaoshan Lu, Junjie Tong, … Changbin Brad Yu·bioRxiv·May 4, 2023
- Preserving Full Spectrum Information in ImagingMass Spectrometry Data Reduction
Roger Moens, Lukasz G. Migas, … Raf Van de Plas·BioinformaticsPeer-reviewed·May 1, 2025
- mzMLb: a future-proof raw mass spectrometry data format based on standards-compliant mzML and optimized for speed and storage requirements
Ranjeet Bhamber, Andris Jankevics, … Andrew W. Dowsey·Journal of Proteome ResearchPeer-reviewed·Aug 31, 2020