henhaobio
Sign in

Magnetic Resonance in MedicineBiophysicsPeer-reviewed journal article

Cardiac diffusion kurtosis imaging in the human heart in vivo using 300mT/m gradients

Maryam AfzaliiD, Sam CoveneyiD, Lars MuelleriD, Sarah F. JonesiD, Fabrizio FasanoiD, John EvansiD, Irvin TehiD, Erica Dall’ArmellinaiD, Filip SzczepankiewicziD, Derek Kenton JonesiD, Jürgen E. SchneideriD

PDFDOIPreprint

Abstract

PurposeDiffusion tensor imaging (DTI) is commonly used in cardiac diffusion magnetic resonance imaging (dMRI). However, the tissues microstructure (cells, membranes, etc.) restricts the movement of the water molecules, making the spin displacements deviate from Gaussian behaviour. This effect may be observed with diffusion kurtosis imaging (DKI) using sufficiently high b-values (b > 450 s/mm2), which are presently outside the realm of routine cardiac dMRI due to the limited gradient strength of clinical scanners. The Connectom scanner with Gmax = 300 mT/m enables high b-values at echo times (TE) similar to DTI on standard clinical scanners, therefore facilitating cardiac DKI in humans. MethodsCardiac-gated, second-order motion-compensated dMRI was performed with bmax = 1350 s/mm2 in 10 healthy volunteers on a 3T MRI scanner with Gmax = 300 mT/m. The signal was fitted to a cumulant expansion up to and including the kurtosis term and diffusion metrics such as fractional anisotropy (FA), mean diffusivity (MD), mean kurtosis (MK), axial kurtosis (AK), and radial kurtosis (RK) were calculated. ResultsWe demonstrate deviation of the signal from monoexponential decay for b-values > 450 s/mm2 (MK = 0.32 {+/-} 0.03). Radial kurtosis (RK = 0.35 {+/-} 0.04) was observed slightly larger than axial kurtosis (AK = 0.27 {+/-} 0.02), and the difference is statistically significant (RK - AK = 0.08 {+/-} 0.04, p = 2e - 4). ConclusionThis work demonstrates the feasibility of quantifying kurtosis effect in the human heart in vivo (at an echo time shorter than typical TEs reported for cardiac DTI), using high-performance gradient systems (which are 4-8 times stronger than on standard clinical scanners). Our work lays the foundation for exploring new biomarkers in cardiac dMRI beyond DTI.

Citations
6
FWCI
3.40
Field percentile
top 7%

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISNovello '22Coveney '25Kasa '20Henriques '21Taha '21Oeschger '23
79% semantic matchNeuroscience
Lisa Novello, Rafael Neto Henriques, Andrada Ianuș+3 more·NeuroImage·Mar 23, 2022· 19 citations