Sign in
PhysiologybioRxiv
Preprint

Exercise Intensity Modulates the Validity of Non-Linear Heart Rate Time Series Analysis Window Length: Implications for DFAa1 Monitoring

J. De Maeseneer, Anton OlieslagersiD, Thomas GronwaldiD, Toon T. de BeukelaariD

Abstract

PurposeDetrended fluctuation analysis alpha-1 (DFAa1) has emerged as a promising non-invasive biomarker for exercise intensity assessment. However, the standard 2-min analysis window lacks temporal resolution necessary for real-time training applications. This study systematically investigated the validity of shortened DFAa1 windows (30s and 1min) versus the 2-min reference across different intensities. MethodsPhysically active males completed three continuous cycling protocols: low-intensity training at the first lactate threshold (LOW, n=19), moderate-intensity training at the second lactate threshold (MOD, n=19), and a 30-min self-paced time trial (TT30, n=18). DFAa1 was calculated using 30-s, 1-min, and 2-min moving windows, advancing in 1s increments. Validity was assessed using intraclass correlation coefficients (ICC), Bland-Altman analysis, and standard error of measurement (SEM). ResultsDuring LOW, both shortened windows showed poor agreement with the 2-min reference (30s: ICC=0.02, mean bias of -0.05; 1min: ICC=0.37, -0.02). During MOD, the 30-s window remained unreliable (ICC=0.32, -0.01), while the 1-min window achieved moderate reliability (ICC=0.63, 0.00). During TT30, both shortened windows substantially improved performance (30s: ICC=0.78, -0.02; 1min: ICC=0.95, -0.01), with the 1-min window achieving excellent reliability. ConclusionDFAa1 analysis window validity is intensity-dependent, with shortened windows showing progressively improved agreement as exercise intensity and heart rate increases. While the 2-min window remains essential for low-intensity monitoring, 1-min or 30-s windows provide appropriate validity during high-intensity exercise, enabling more-responsive real-time feedback. These results support adaptive windowing strategies that dynamically adjust window length based on exercise intensity and the number of included data points, to optimize the analytical validity-temporal responsiveness trade-off.

02 /Specification & Classification

Click any tag to browse matching papers

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISMorrow '26Marmelat '19Samaha '23Drapeau '19Goudini '24Mansfield '25
60% semantic matchNeuroscience
Audrey Morrow, Montana Wilson, Michaela Geller-Montague+3 more·Imaging Neuroscience·Jan 1, 2026· 2 citations