Exercise Intensity Modulates the Validity of Non-Linear Heart Rate Time Series Analysis Window Length: Implications for DFAa1 Monitoring
J. De Maeseneer, Anton OlieslagersiD, Thomas GronwaldiD, Toon T. de BeukelaariD
Abstract
PurposeDetrended fluctuation analysis alpha-1 (DFAa1) has emerged as a promising non-invasive biomarker for exercise intensity assessment. However, the standard 2-min analysis window lacks temporal resolution necessary for real-time training applications. This study systematically investigated the validity of shortened DFAa1 windows (30s and 1min) versus the 2-min reference across different intensities. MethodsPhysically active males completed three continuous cycling protocols: low-intensity training at the first lactate threshold (LOW, n=19), moderate-intensity training at the second lactate threshold (MOD, n=19), and a 30-min self-paced time trial (TT30, n=18). DFAa1 was calculated using 30-s, 1-min, and 2-min moving windows, advancing in 1s increments. Validity was assessed using intraclass correlation coefficients (ICC), Bland-Altman analysis, and standard error of measurement (SEM). ResultsDuring LOW, both shortened windows showed poor agreement with the 2-min reference (30s: ICC=0.02, mean bias of -0.05; 1min: ICC=0.37, -0.02). During MOD, the 30-s window remained unreliable (ICC=0.32, -0.01), while the 1-min window achieved moderate reliability (ICC=0.63, 0.00). During TT30, both shortened windows substantially improved performance (30s: ICC=0.78, -0.02; 1min: ICC=0.95, -0.01), with the 1-min window achieving excellent reliability. ConclusionDFAa1 analysis window validity is intensity-dependent, with shortened windows showing progressively improved agreement as exercise intensity and heart rate increases. While the 2-min window remains essential for low-intensity monitoring, 1-min or 30-s windows provide appropriate validity during high-intensity exercise, enabling more-responsive real-time feedback. These results support adaptive windowing strategies that dynamically adjust window length based on exercise intensity and the number of included data points, to optimize the analytical validity-temporal responsiveness trade-off.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Individual Alpha Frequency Predicts the Sensitivity of Time Perception
Audrey Morrow, Montana Wilson, … Jason Samaha·Imaging NeurosciencePeer-reviewed·Jan 1, 2026
- Effect of sampling frequency on fractal fluctuations during treadmill walking
V. Marmelat, A. Duncan, S. Meltz·bioRxiv·Oct 6, 2019
- Alpha-band frequency and temporal windows in perception: A review and living meta-analysis of 27 experiments (and counting)
Jason Samaha, Vincenzo Romei·Journal of Cognitive NeurosciencePeer-reviewed·Oct 19, 2023
- Dynamic cerebral autoregulation of endurance-trained men following 6 weeks of high-intensity interval training to exhaustion
A. Drapeau, L. Labrecque, … P. Brassard·bioRxiv·Apr 11, 2019
- The Effects of Physical and Mental Fatigue on Time Perception
Reza Goudini, Ali Zahiri, … David George Behm·SportsPeer-reviewed·Feb 15, 2024
- Validity of measures of reactive balance training intensity
Avril Mansfield, Sarah Thompson, … George Mochizuki·bioRxiv·Aug 6, 2025