Nature MethodsNeurosciencePeer-reviewed journal article
TDM: a temporal decomposition method for removing venous effects from task-based fMRI
Kendrick KayiD, Keith Wakefield JamisoniD, Ru‐Yuan ZhangiD, Kǎmil UǧurbiliD
Abstract
Most functional magnetic resonance imaging (fMRI) is conducted with gradient-echo pulse sequences. Although this yields high sensitivity to blood oxygenation level dependent (BOLD) signals, gradient-echo acquisitions are heavily influenced by venous effects which limit the ultimate spatial resolution and spatial accuracy of fMRI. While alternative acquisition methods such as spin-echo can be used to mitigate venous effects, these methods lead to serious reductions in signal-to-noise ratio and spatial coverage, and are difficult to implement without leakage of undesirable non-spin-echo effects into the data. Moreover, analysis heuristics such as masking veins or sampling inner cortical depths using high-resolution fMRI may be helpful, but sacrifice information from many parts of the brain. Here, we describe a new analysis method that is compatible with conventional gradient-echo acquisition and provides venous-free response estimates throughout the entire imaged volume. The method involves fitting a low-dimensional manifold characterizing variation in response timecourses observed in a given dataset, and then using identified early and late timecourses as basis functions for decomposing responses into components related to the microvasculature (capillaries and small venules) and the macrovasculature (veins), respectively. We show that this Temporal Decomposition through Manifold Fitting (TDM) method is robust, consistently deriving meaningful timecourses in individual fMRI scan sessions. Moreover, we show that by removing late components, TDM substantially reduces the superficial cortical depth bias present in gradient-echo BOLD responses and eliminates artifacts in cortical activity maps. TDM is general: it can be applied to any task-based fMRI experiment, can be used with standard- or high-resolution fMRI acquisitions, and can even be used to remove residual venous effects from specialized acquisition methods like spin-echo. We suggest that TDM is a powerful method that improves the spatial accuracy of fMRI and provides insight into the origins of the BOLD signal.
- Citations
- 45
- FWCI
- 3.16
- Field percentile
- top 6%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- A critical assessment of data quality and venous effects in ultra-high-resolution fMRI
Kendrick Kay, Keith Wakefield Jamison, … Kǎmil Uǧurbil·NeuroImagePeer-reviewed·Feb 5, 2019
- Improving the temporal accuracy of functional Magnetic Resonance Imaging
Niels Janssen, Juan A. Hernández-Cabrera, Laura Ezama Foronda·bioRxiv·Sep 5, 2016
- Simultaneous pure T2 and varying T2'-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses
Fuyixue Wang, Zijing Dong, … Kawin Setsompop·NeuroImagePeer-reviewed·Oct 14, 2021
- Enabling brain-wide mapping of layer-specific functional connectivity at 3T via layer-dependent fMRI with draining-vein suppression
Wei‐Tang Chang, Weili Lin, Kelly S. Giovanello·eLifePeer-reviewed·Apr 21, 2026
- Hi-Fi fMRI: High-resolution, fast-sampled and sub-second whole-brain functional MRI at 3T in humans
Benedetta Franceschiello, Simone Rumac, … Eleonora Fornari·bioRxiv·May 13, 2023
- Correcting for Superficial Bias in 7T Gradient Echo fMRI
Pei Huang, Marta Correia, … Johan D. Carlin·Frontiers in NeurosciencePeer-reviewed·Sep 22, 2021