Simultaneous pure T2 and varying T2'-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses
Fuyixue WangiD, Zijing DongiD, Lawrence L. WaldiD, Jon̈athan R. PolimeniiD, Kawin SetsompopiD
Abstract
Spin-echo (SE) BOLD fMRI has high microvascular specificity, and thus provides a more reliable means to localize neural activity compared to conventional gradient-echo BOLD fMRI. However, the most common SE BOLD acquisition method, SE-EPI, is known to suffer from T2' contrast contamination with undesirable draining vein bias. To address this, in this study, we extended a recently developed distortion/blurring-free multi-shot EPI technique, Echo-Planar Time-resolved Imaging (EPTI), to cortical-depth dependent SE-fMRI at 7T to test whether it could provide purer SE BOLD contrast with minimal T2' contamination for improved neuronal specificity. From the same acquisition, the time-resolved feature of EPTI also provides a series of asymmetric SE (ASE) images with varying T2' weightings, and enables extraction of data equivalent to conventional SE EPI with different echo train lengths (ETLs). This allows us to systematically examine how T2'-contribution affects different SE acquisition strategies using a single dataset. A low-rank spatiotemporal subspace reconstruction was implemented for the SE-EPTI acquisition, which incorporates corrections for both shot-to-shot phase variations and dynamic B0 drifts. SE-EPTI was used in a visual task fMRI experiment to demonstrate that i) the pure SE image provided by EPTI results in the highest microvascular specificity; ii) the ASE EPTI series, with a graded introduction of T2' weightings at time points farther away from the pure SE, show a gradual sensitivity increase along with increasing draining vein bias; iii) the longer ETL seen in conventional SE EPI acquisitions will induce more draining vein bias. Consistent results were observed across multiple subjects, demonstrating the robustness of the proposed technique for SE-BOLD fMRI with high specificity.
- Citations
- 16
- FWCI
- 1.45
- Field percentile
- top 19%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Microvascular Specificity of Spin Echo BOLD fMRI: Impact of EPI Echo Train Length
Tanya W.P. van Horen, Jeroen C.W. Siero, … Mario Gilberto Báez‐Yáñez·bioRxiv·Sep 15, 2023
- Spatial specificity of the functional gradient echo and spin echo BOLD signal across cortical depth at 7 T
Daniel Haenelt, Robert Trampel, … Nikolaus Weiskopf·bioRxiv·Jul 28, 2025
- Single-shot Echo Planar Time-resolved Imaging for multi-echo functional MRI and distortion-free diffusion imaging
Z. Dong, L. L. Wald, … F. Wang·bioRxiv·Jan 24, 2024
- TDM: a temporal decomposition method for removing venous effects from task-based fMRI
Kendrick Kay, Keith Wakefield Jamison, … Kǎmil Uǧurbil·Nature MethodsPeer-reviewed·Sep 7, 2020
- Macrovascular contributions to resting-state fMRI signals: A comparison between EPI and bSSFP at 9.4 Tesla
D. Ramadan, Sebastian Mueller, … J Bause·Imaging NeurosciencePeer-reviewed·Dec 18, 2024
- Asymmetric spin echo multi-echo echo planar imaging (ASEME-EPI) sequence for pre-clinical high-field fMRI
Kyle A. Johnson, Christopher P. Pawela, … Jason W. Sidabras·bioRxiv·Oct 12, 2024