Evaluating discordant somatic calls across mutation discovery approaches to minimize false negative drug-resistant findings
Hsin-Fu LiniD, Pei-Miao Chien, Chin-Yi ChengiD, Tzu‐Hang Yuan, Yubin WangiD, Pei‐Lung CheniD, Chien‐Yu CheniD, Jia‐Hsin HuangiD, Jacob Shujui HsuiD
Abstract
Evaluating robustness of somatic mutation detections is essential when utilizing whole exome sequencing (WES) for treatment decision-making. A comprehensive evaluation was conducted using tumor WES from the FDA-led Sequencing Quality Control Phase 2 (SEQC2) project, in which multiple library kits sequenced identical DNA materials across three labs to benchmark analytical validity. These workflows included various read aligner (BWA, Bowtie2, DRAGEN-Aligner, DRAGMAP, and HISAT2) and mutation caller (Mutect2, TNscope, DRAGEN-Caller, and DeepVariant) combinations. The results revealed that DRAGEN exhibited superior performance, achieving mean F1-scores of 0.966 and 0.791 for SNV and INDEL detection, respectively. Among open-source software, BWA Mutect2 and HISAT2 Mutect2 combinations showed the highest mean F1-scores for SNV (0.949) and IN-DEL (0.722), respectively. The analyses indicated that high-quality data can be analyzed as having worse results, and vice versa. Evaluations of COSMIC reported mutations unveiled discrepancies across enrichment kits. IDT enrichment kits showed a higher false negative rate, while Agilent WES kits tended to miss mutations in CBL and IDH1, and Roche library kits tended to miss the mutations in PIK3CB. For drug-related biomarkers, Sentieon TNscope tended to underestimate tumor mutation burden and overlook crucial drug-resistance mutations such as FLT3 (c.G1879A: p.A627T) for cytarabine resistance in leukemia and MAP2K1 (c.G199A:p.D67N) for BRAF inhibitors in melanoma. The findings highlight the importance of robust bioinformatic analysis in identifying tumor mutations and guiding clinical decision-making. HighlightsO_LIMutation callers had a significantly higher effect on overall sensitivity than aligners. C_LIO_LIBenchmarking analyses demonstrated that high-quality sequencing reads can be analyzed as having worse results, and vice versa. C_LIO_LIDRAGEN exhibited the best performance among other aligner-caller combinations. C_LIO_LIThe combination of BWA with Mutect2 and HISAT2 with Mutect2 yielded the highest mean F1 scores for detecting SNVs and INDELs by open-source software, respectively. C_LIO_LISentieon TNscope tended to underestimate the tumor mutation burden and missed several drug-resistant mutations. C_LI
- organism: human
- assay: whole-exome sequencing
- research focus: variant calling
- approach: statistical model
- Citations
- 1
- FWCI
- 0.45
- Field percentile
- top 43%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Evaluating the analytical validity of mutation calling pipeline for tumor whole exome sequencing
Chinyi Cheng, Jia‐Hsin Huang, Jacob Shujui Hsu·bioRxiv·Nov 17, 2022
- Accuracy of somatic variant detection workflows for whole genome sequencing experiments
Roman Jaksik, Jacek Rosiak, … Paweł Sztromwasser·bioRxiv·Jun 10, 2021
- Evaluation of somatic variant calling methods on high coverage tumour-only amplicon sequencing data in a clinical environment
Dhammapal Bharne, Daniel Gaston·bioRxiv·Apr 11, 2026
- Achieving reproducibility and accuracy in cancer mutation detection with whole-genome and whole-exome sequencing
Wenming Xiao, Luyao Ren, … Leming M. Shi·Nature BiotechnologyPeer-reviewed·Sep 1, 2021
- Variant calling pipelines for whole exome sequencing in clinical context
Johanna Stepanian, Diego Saldaña, … Jorge Diaz·medRxiv·Oct 18, 2024
- A Weighted Estimation Approach to Correct for Imperfect Mutation Detection Due to Intra-tumor Heterogeneity in Tumor Sequencing
Audrey Mauguen, Irina Ostrovnaya·bioRxiv·Oct 8, 2026