Abstract
BackgroundAmbulatory measurements of trunk accelerations can provide valuable insight into the amount and quality of daily life activities. Such information has been used to create models that aim to identify individuals at high risk of falls. However, external validation of such prediction models is lacking, yet crucial for clinical implementation. We externally validated three previously described fall prediction models (van Schooten et al., 2015a). MethodsComplete questionnaires and one week of trunk acceleration data were obtained in 263 community-dwelling people (mean age 71.8 years, 68.1% female). To validate models, we first used the coefficients and optimal cut-offs from original cohort, then recalibrated the original models, as well as optimized parameters based on our new cohort. ResultsAmong all participants, 39.9% experienced falls during 6-month follow-up. All models showed poor precision (0.20-0.49), poor sensitivity (0.32-0.58), and good specificity (0.45-0.89). Calibration of the original models had limited effect on model performance. Using coefficients and cut-offs optimized on the external cohort also had limited benefit. Last, the odds ratios in our cohort were different from those in the original cohort and indicated that gait characteristics, except for index of harmonicity ML, were not statistically significantly associated with falls. ConclusionsPrediction of fall risk in our cohort was not as effective as in the original cohort. Recalibration as well as optimized model parameters resulted in limited increase in accuracy. Fall prediction models are highly specific to the cohort studied. This highlights the need for large representative cohorts, preferably with an external validation cohort.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- An open-source, externally validated neural network algorithm to recognize daily life gait of older adults based on the lower-back sensor
Yuge Zhang, Sjoerd M. Bruijn, … Sina David·Medical & Biological Engineering & ComputingPeer-reviewed·Oct 22, 2025
- Predicting the risk of sarcopenia in elderly patients with patellar fracture: Development and assessment of a new predictive nomogram
Yisheng Chen, Yan-xian Cai, … Jie Tao·PeerJPeer-reviewed·Apr 15, 2020
- The validation of new phase-dependent gait stability measures: a modelling approach
J. Jin, D. Kistemaker, … S. Bruijn·bioRxiv·Jun 18, 2020
- Phase-dependent gait robustness is not related to phase-dependent gait stability
D. Kistemaker, J. Jin, … S. M. Bruijn·bioRxiv·Sep 20, 2022
- Generic versus personalized foot-ground contact models for predictive simulations of walking: Is personalization worth the effort?
Spencer T. Williams, Geng Li, Benjamin Jon Fregly·Annals of Biomedical EngineeringPeer-reviewed·Oct 26, 2026
- Predicting drowning from sea and weather forecasts: development and validation of a model on surf beaches of southwestern France.
E. Tellier, B. Simonnet, … L. R. Salmi·bioRxiv·Jul 31, 2019