bioRxivBiophysicsPreprint
An assessment of the fixin tplo jig to generate effective compression using a transverse fracture model
Abstract
The objective of this study was to determine compressive loads that could be generated using a tibial plateau leveling osteotomy (TPLO) jig with a tensioned strand of 18-gauge stainless steel orthopedic wire in a simulated transverse fracture model. The wire was sequentially tensioned using heavy needle holders or an AO wire tightener. Recorded loads were subsequently compared to loads generated by applying a 3.5 mm limited contact-dynamic compression plate (LC-DCP) as a compression plate. Two segments of 2 cm diameter Delrin rod were placed in a testing apparatus and used to simulate a transverse fracture. A load cell was interposed between the two segments to measure the compressive loads generated during the application of the TPLO jig or the LC-DCP. Compression was generated by sequential tensioning a strand of 18-gauge wire secured through the base of the arms of the TPLO jig or by placing one or two load screws in the LC-DCP. Wires were tensioned using heavy needle holders or an AO wire tightener. Eight replicates of each construct were tested. Recorded loads were compared using a one-way repeated measures ANOVA and Tukey Honestly Significant Difference test. The wire being tensioned broke while attempting a second quarter rotation of the needle holders and when the crank handle of the AO wire tightener was advanced beyond two rotations. The mean + SD peak compressive loads recorded when tensioning the wire using the heavy needle holders and AO wire tightener was 148 {+/-} 7 N and 217 {+/-} 16 N, respectfully. The mean {+/-} SD load recorded after placement of the first and second load screw in the LC-DCP was 131 {+/-} 39 N and 296 {+/-} 49 N, respectively. The compression generated by placing two load screws in the LC-DCP was superior to the compression generated using the jig. The maximum load recorded by tensioning the wire secured through the TPLO jig using the AO wire tightener was superior to the compression generated by placing a single load screw and tensioning the wire using needle holders. Our results demonstrate that the TPLO jig allows surgeons to compress transverse fractures or osteotomies effectively. Tensioning the AO wire tightener allows for sequential tensioning and generates superior compressive loads than tensioning wires with heavy needle holders.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- ANALYSIS AND IMPLICATIONS OF COMPLIANCE IN JOINT BIOMECHANICS SUPERPOSITION TESTING
Callan M. Gillespie, Nicholas J. Haas, … Robb Colbrunn·Journal of Biomechanical EngineeringPeer-reviewed·May 9, 2025
- Measuring Orthopedic Plate Strain to Track Bone Healing Using a Fluidic Sensor Read via Plain Radiography
A. Rajamanthrilage, M. Arifuzzaman, … J. N. Anker·bioRxiv·Aug 27, 2020
- Development of Multi-Bundle Virtual Ligaments to Simulate Knee Mechanics after Total Knee Arthroplasty
S. Vakili, B. Lanting, … R. Willing·bioRxiv·Oct 12, 2022
- An Adjustable Offloading Ankle-Foot Orthosis: Design and Proof-of-Concept Biomechanical Verification
Eshraq Saffuri, Lee Jordan, Dana Solav·bioRxiv·May 20, 2026
- Fibrin Prestress Due to Platelet Aggregation and Contraction Increases Clot Stiffness
S. J. Pathare, W. Eng, … A. Ramasubramanian·bioRxiv·Apr 19, 2021
- Core bone diameter in an organic implant-less technique affecting the biomechanical properties of the anterior cruciate ligament fixation; an in-vitro study
M. Mohseni, A. Nourani, … M. Chizari·bioRxiv·Jul 12, 2021