Precision Brain Morphometry: Feasibility and Opportunities of Extreme Rapid Scans
Jared Allen NielseniD, Ross William MairiD, Justin Taylor BakeriD, Randy L. BuckneriD
Abstract
The traditional approach to achieve optimal structural brain morphometry is to increase spatial resolution and maintain a high signal-to-noise ratio within a single scanning session using long acquisitions. Here we explore alternative approaches that use multiple rapid structural scans and averaging to achieve stable morphometric estimates. Effects of sequence, resolution, acceleration, and number of scans within- and between-sessions were varied across six studies that included 1,025 scans. Single ~1-min magnetization-prepared rapid gradient echo (MP-RAGE) scans that use wave-controlled aliasing in parallel imaging (Wave-CAIPI) encoding yield morphometric estimates nearly as accurate as those obtained with traditional long scans. Averaging estimates from multiple rapid scans reduces error below traditional approaches using less total acquisition time. Test-retest reliability within- and between-sessions for ~2 min multi-echo MP-RAGE scans revealed that a source of error is the idiosyncratic positioning of the subject's head between sessions. Cluster scanning over multiple tightly-spaced sessions mitigates this effect and achieves cortical thickness estimates with less than 10m global (30m regional) error. Test-retest error for the hippocampus falls below 0.6%. Additional sources of error include coil heating when scans are acquired rapidly within the same session and change in console software between sessions. Rapid acquisitions allow novel experimental designs that can use cluster scanning to achieve precise longitudinal assessment within the individual, build in robustness by affording redundant acquisitions, and reduce the structural scanning burden to a minute when anatomical registration is the goal. The field should consider replacing long structural scans with fast alternatives.
- Citations
- 11
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Estimation of in-scanner head pose changes during structural MRI using a convolutional neural network trained on eye tracker video
Heath Pardoe, Samantha P. Martin, … Orrin Devinsky·Magnetic Resonance ImagingPeer-reviewed·Jun 18, 2021
- Estimating the effect of a scanner upgrade on measures of grey matter structure for longitudinal designs
Evelyn Medawar, Ronja Thieleking, … Frauke Beyer·PLoS ONEPeer-reviewed·Oct 5, 2021
- Normalization of MRI T1w between-scan effects for improved longitudinal volumetric estimates
Donatas Sederevičius, Atle Bjørnerud, … Anders M. Fjell·bioRxiv·Jun 19, 2022
- Is it Time to Switch Your T1W Sequence? Assessing the Impact of Prospective Motion Correction on the Reliability and Quality of Structural Imaging
Lei Ai, Richard Cameron Craddock, … Alexandre R. Franco·NeuroImagePeer-reviewed·Nov 25, 2020
- Tissue volume estimation and age prediction using rapid structural brain scans
Harriet Hobday, James Howard Cole, … František Váša·Scientific ReportsPeer-reviewed·Jul 14, 2022
- Hi-Fi fMRI: High-resolution, fast-sampled and sub-second whole-brain functional MRI at 3T in humans
Benedetta Franceschiello, Simone Rumac, … Eleonora Fornari·bioRxiv·May 13, 2023