Verifying the concordance between motion corrected and conventional MPRAGE for pediatric morphometric analysis
Barat Gal-EriD, Yannick BrackenieriD, Alexandra F. BonthroneiD, Chiara CasellaiD, Anthony N. PriceiD, Sophie ArulkumaraniD, Andrew T. M. ChewiD, Chiara NosartiiD, Michela CleriiD, Pierluigi Di CiòiD, Alexia M. EgloffiD, Mary RutherfordiD, Jonathan O’MuircheartaighiD, Raphaël Tomi‐TricotiD, Shaihan MalikiD, Lucilio Cordero‐GrandeiD, Joseph V. HajnaliD, Serena Jane CounselliD
Abstract
PurposeTo validate a retrospective motion correction technique, Distributed and Incoherent Sample Orders for Reconstruction Deblurring using Encoding Redundancy (DISORDER), for pediatric brain morphometry. MethodsTwo T1-weighted MPRAGE 3D datasets were acquired at 3T in thirty-seven children, median age 7.75 years; one with conventional linear phase encoding and one using DISORDER. MPRAGE images were scored as motion-free or motion-corrupt. Cortical morphometry and regional brain volumes were measured with FreeSurfer, subcortical grey matter (GM) with FSL-FIRST, and hippocampal volumes with HippUnfold. Intraclass correlation coefficient (ICC) was used to determine agreement between the 2 MPRAGE acquisitions. Mann-Whitney U was used to test the difference between measures obtained using DISORDER and (i) motion-free and (ii) motion-corrupt conventional MPRAGE data. ResultsICC measures were good/excellent for most subcortical GM (motion-free, 0.75-0.96; motion-corrupt, 0.62-0.98) and regional brain volumes (motion-free 0.47-0.99; motion-corrupt, 0.54-0.99) between conventional MPRAGE and DISORDER data, except for the amygdala and nucleus accumbens (motion-free, 0.38-0.65; motion- corrupt, 0.1-0.42). However, these values were less consistent for motion-corrupt conventional MPRAGE data for hippocampal volumes (motion-free 0.65-0.99; motion-corrupt, 0.11-0.91) and cortical measures (motion-free 0.76-0.98; motion- corrupt, 0.09-0.74). Mann-Whitney U showed percentage differences in measures obtained with motion-corrupt conventional MPRAGE compared to DISORDER data were significantly greater than in those obtained using motion-free conventional MPRAGE data in 22/58 structures. ConclusionIn the absence of motion, morphometric measures obtained using DISORDER are largely consistent with those from conventional MPRAGE data, whereas improved reliability is obtained by DISORDER for motion-degraded scans. This study validates DISORDER for brain morphometric studies in children.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 2
- FWCI
- 1.15
- Field percentile
- top 26%
- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Is it Time to Switch Your T1W Sequence? Assessing the Impact of Prospective Motion Correction on the Reliability and Quality of Structural Imaging
Lei Ai, Richard Cameron Craddock, … Alexandre R. Franco·NeuroImagePeer-reviewed·Nov 25, 2020
- Head motion during fMRI tasks is reduced in children and adults if participants take breaks
Tobias W. Meissner, Jon Walbrin, … Sarah Weigelt·Developmental Cognitive NeurosciencePeer-reviewed·May 29, 2020
- Differences in the spatial and temporal patterns of head motion during MRI of adults and infants
Rhodri Cusack, Annika Carola Linke, … Conor J. Wild·bioRxiv·Mar 6, 2017
- MR-PET head motion correction based on co-registration of multi-contrast MR images
Zhaolin Chen, Francesco Sforazzini, … Gary F. Egan·Human Brain MappingPeer-reviewed·Jan 3, 2019
- Implementation of a pre- and in-scan system to minimize head motion in pediatric participants undergoing fMRI scans
Corey L. Horien, Scuddy Fontenelle, … Robert Todd Constable·bioRxiv·Mar 4, 2020
- Prospective Motion correction improves the sensitivity of fMRI pattern decoding
Pei Huang, Johan D. Carlin, … Marta Correia·Human Brain MappingPeer-reviewed·Jun 8, 2018