bioRxivBioinformaticsPreprint
Conservative method for attenuation of Vertical Electrooculogram based on local suppression of artifact templates from ongoing EEG
Dimitri Marques AbramoviD, Carlos Alberto Mourão JúnioriD, Paulo Ricardo Galhanone, Vladimir V. LazareviD
Abstract
BackgroundEye movement during blinking can be a significant artifact in ERP analysis (mainly if ERP is blink-locked). Blinks produce a large positive potential in the vertical electrooculogram (VEOG), spreading towards posterior direction. Two methods are the most frequently used to suppress VEOGs: linear regression to subtract the VEOG signal from each EEG channel and Independent Component Analysis (ICA). However, both lose some EEG information.\n\nMethodsThe present algorithm (1) statistically identifies the time position of VEOGs in the frontopolar channels; (2) performs EEG averaging for each channel, which results in blink templates; (3) subtracts each template from the respective EEG at each VEOG position, only when the linear correlation index between the template and the segment is greater than a threshold L. The signals from twenty subjects were acquired using a behavioral test and were treated using FilterBlink for subsequent ERP analysis. A model was designed to test the method for each subject using twenty copies of the EEG signal from the mid-central channel of the subject (which has almost no VEOG) representing each one of the 20 EEG channels and their respective blink templates. At the same 200 equidistant time points (marks), a signal (2.5 sinusoidal cycles at 1050 ms to emulate an ERP) was mixed with each model channel, along with the respective blink template of that channel, between 500 to 1200 ms after each mark.\n\nResultsAccording to the model, VEOGs interfered with both ERPs and the ongoing EEG mainly on the anterior medial leads, and no significant effect was observed on the mid-central channel (Cz). FilterBlink recovered approximately 90% (at Fp1) to 98% (Fz) of the original ERP and EEG signals to L of 0.1. In the analysis of real signals, the method reduced drastically the VEOG effect on the EEG after ERP and blink-artifact averaging.\n\nConclusionThe method is very simple and effective for VEOG attenuation without significant distortion of the EEG signal and embedded ERPs in all channels.
- assay: electronic health records
- research focus: batch correction / integration
- approach: statistical model
- Citations
- 2
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Combining eye tracking with EEG: Effects of filter settings on EEG for trials containing task relevant eye-movements
Louisa Kulke, Vincent Kulke·bioRxiv·Apr 22, 2020
- EEG is better when cleaning effectively targets artifacts
Neil Wayne Bailey, Aron T. Hill, … Paul Bernard Fitzgerald·Clinical NeurophysiologyPeer-reviewed·Oct 10, 2025
- Evaluating the Effectiveness of Artifact Correction and Rejection in Event-related Potential Research
Guanghui Zhang, David R. Garrett, … Steven J. Luck·PsychophysiologyPeer-reviewed·Jan 2, 2024
- Removing mains power artefacts from EEG - a novel template-based method
S. Zhang, B. McCane, … N. McNaughton·bioRxiv·Jan 27, 2020
- Removing EOG Artifacts From EEG Recordings using Deep Learning
Christian O’Reilly, S. Huberty·bioRxiv·May 24, 2024
- Introducing RELAX (the Reduction of Electroencephalographic Artifacts): A fully automated pre-processing pipeline for cleaning EEG data - Part 2: Application to Event-Related Potentials
Neil Wayne Bailey, Aron T. Hill, … Paul Bernard Fitzgerald·Clinical NeurophysiologyPeer-reviewed·Feb 13, 2023