Simulation of the effect of diffusion on asymmetric spin echo based quantitative BOLD: An investigation of the origin of deoxygenated blood volume overestimation
Alan J. StoneiD, Naomi C Holland, Avery J.L. BermaniD, Nicholas P. BlockleyiD
Abstract
Quantitative BOLD (qBOLD) is a technique for mapping oxygen extraction fraction (OEF) and deoxygenated blood volume (DBV) in the human brain. Recent measurements using an asymmetric spin echo (ASE) based qBOLD approach produced estimates of DBV which were systematically higher than measurements from other techniques. In this study, we investigate two hypotheses for the origin of this DBV overestimation using simulations and consider the implications for experimental measurements. Investigations were performed by combining Monte Carlo simulations of extravascular signal with an analytical model of the intravascular signal.\n\nHypothesis 1DBV overestimation is due to the presence of intravascular signal which is not accounted for in the analysis model. Intravascular signal was found to have a weak effect on qBOLD parameter estimates.\n\nHypothesis 2DBV overestimation is due to the effects of diffusion which are not accounted for in the analysis model. The effect of diffusion on the extravascular signal was found to result in a vessel radius dependent variation in qBOLD parameter estimates. In particular, DBV overestimation peaks for vessels with radii from 20 to 30 m and is OEF dependent. This results in the systematic underestimation of OEF.\n\nImplicationsThe impact on experimental qBOLD measurements was investigated by simulating a more physiologically realistic distribution of vessel sizes with a small number of discrete radii. Overestimation of DBV consistent with previous experiments was observed, which was also found to be OEF dependent. This results in the progressive underestimation of the measured OEF. Furthermore, the relationship between the measured OEF and the true OEF was found to be dependent on echo time and spin echo displacement time.\n\nThe results of this study demonstrate the limitations of current ASE based qBOLD measurements and provide a foundation for the optimisation of future acquisition approaches.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 18
- FWCI
- 1.49
- Field percentile
- top 19%
- Organism
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Improving qBOLD based measures of oxygen extraction fraction using hyperoxia-BOLD derived measures of blood volume
A. J. Stone, N. P. Blockley·bioRxiv·Jun 14, 2020
- Evaluating BOLD functional MRI biophysical simulation approaches: impact of vascular geometry, magnetic field calculations, and water diffusion models
Avery J.L. Berman, Jacob Chaussé, … J. Jean Chen·Imaging NeurosciencePeer-reviewed·Jan 1, 2026
- On the influence of the vascular architecture on Gradient Echo and Spin Echo BOLD fMRI signals across cortical depth: a simulation approach based on realistic 3D vascular networks
Mario Gilberto Báez‐Yáñez, Jeroen C.W. Siero, … Natalia Petridou·bioRxiv·May 30, 2024
- Serial quantification of brain oxygenation in acute stroke using streamlined-qBOLD
Alan J. Stone, George Harston, … Nicholas P. Blockley·Human Brain MappingPeer-reviewed·Mar 12, 2019
- Comparison of compartmental analytical BOLD fMRI models against Monte Carlo simulations performed over cortical micro-angiograms
Jordan Charest, Mathieu Walsh, … Michèle Desjardins·NMR in BiomedicinePeer-reviewed·Sep 8, 2024
- Perfusion Quantification in the Human Brain Using DSC MRI - Simulations and Validations at 3T
J. B. Schulman, E. S. Sayin, … K. Uludag·bioRxiv·Apr 27, 2022