eNeuroNeurosciencePeer-reviewed journal article
Failed stopping transiently suppresses the electromyogram in task-irrelevant muscles
Isaiah Mills, Mitchell Grant Fisher, Corey George WadsleyiD, Ian GreenhouseiD
Abstract
Selectively stopping individual parts of planned or ongoing movements is an everyday motor skill. For example, while walking in public you may stop yourself from waving at a stranger who you mistook for a friend while continuing to walk. Despite its ubiquity, our ability to selectively stop actions is limited. Canceling one action can delay the execution of other simultaneous actions. This stopping-interference effect on continuing actions during selective stopping may be attributed to a global inhibitory mechanism with widespread effects on the motor system. Previous studies have characterized a transient global reduction in corticomotor excitability by combining brain stimulation with electromyography (EMG). Here, we examined whether global motor inhibition during selective stopping can be measured peripherally and with high temporal resolution using EMG alone. Eighteen participants performed a bimanual anticipatory response inhibition task with their index fingers while maintaining a tonic contraction of the task-irrelevant abductor digiti minimi (ADM) muscles. A time series analysis of the ADM EMG signal revealed transient inhibition during failed stopping compared to go response trials 150 ms to 203 ms following the stop signal. The pattern was observed in both hands during bimanual stop-all trials as well as selective stop-left and stop-right trials of either hand. These results indicate that tonic muscle activity is sensitive to the effects of global motor suppression even when stopping fails. Therefore, EMG can provide a physiological marker of global motor inhibition to probe the time course and extent of stopping processes. Key PointsO_LISuccessfully stopping an initiated response globally suppresses the motor system. C_LIO_LIUsing electromyography of tonic muscle activity, we show inhibition spills over to task-irrelevant muscles during failed stopping. C_LIO_LIThe electromyographic pattern of inhibition is transient, lasting from approximately 150 to 203 ms following a stop signal when stopping fails. C_LIO_LIThe time course of the peripheral suppression of muscle activity may be leveraged to more precisely examine candidate neural mechanisms. C_LIO_LIThis non-invasive measure of motor system inhibition may be useful for tracking inhibitory control deficits in clinical populations. C_LI
- organism: human
- assay: electronic health records
- research focus: cell type annotation
- research focus: clustering
- research focus: differential expression
- research focus: gene regulatory network inference
- approach: statistical model
- Citations
- 4
- FWCI
- 1.70
- Field percentile
- top 20%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Early rise and persistent inhibition of electromyography during failed stopping
Mitchell Grant Fisher, Hoa Trinh, … Ian Greenhouse·Journal of Cognitive NeurosciencePeer-reviewed·Jan 1, 2024
- Global motor system suppression as the primary mechanism of human action stopping: challenging the pause-then-cancel model
Eashan Ray Chaudhuri, Tiombe Long, Ricci Hannah·Journal of NeurosciencePeer-reviewed·Aug 1, 2025
- An exploration of complex action stopping across multiple datasets: Insights into the mechanisms of action cancellation and re-programming
Sauro E. Salomoni, Simon Weber, Mark R. Hinder·CortexPeer-reviewed·Feb 28, 2025
- A single mechanism for global and selective response inhibition under the influence of motor preparation
Liisa Raud, Rene Jürgen Huster, … Ian Greenhouse·Journal of NeurosciencePeer-reviewed·Sep 14, 2020
- Partial response electromyography as a marker of action stopping
Liisa Raud, Christina Thunberg, Rene Jürgen Huster·eLifePeer-reviewed·May 26, 2022
- The Contextual Specificity of Pausing: Interpreting Electromyographic Partial Responses During Action Cancellation and Attentional Capture
Simon Weber, Keegan Haugh, … Mark R. Hinder·bioRxiv·Jul 29, 2026