Framewise multi-echo distortion correction for superior functional MRI
A. N. Van, D. F. Montez, T. O. Laumann, V. Suljic, T. Madison, N. J. Baden, N. Ramirez-Perez, K. M. Scheidter, J. S. Monk, F. I. Whiting, B. Adeyemo, R. J. Chauvin, S. R. Krimmel, A. Metoki, A. Rajesh, J. L. Roland, T. Salo, A. Wang, K. B. Weldon, A. Sotiras, J. S. Shimony, B. P. Kay, S. M. Nelson, B. Tervo-Clemmens, S. A. Marek, , N. U. F. Dosenbach
Abstract
Functional MRI (fMRI) data are severely distorted by magnetic field (B0) inhomogeneities which currently must be corrected using separately acquired field map data. However, changes in the head position of a scanning participant across fMRI frames can cause changes in the B0 field, preventing accurate correction of geometric distortions. Additionally, field maps can be corrupted by movement during their acquisition, preventing distortion correction altogether. In this study, we use phase information from multi-echo (ME) fMRI data to dynamically sample distortion due to fluctuating B0 field inhomogeneity across frames by acquiring multiple echoes during a single EPI readout. Our distortion correction approach, MEDIC (Multi-Echo DIstortion Correction), accurately estimates B0 related distortions for each frame of multi-echo fMRI data. Here, we demonstrate that MEDICs framewise distortion correction produces improved alignment to anatomy and decreases the impact of head motion on resting-state functional connectivity (RSFC) maps, in higher motion data, when compared to the prior gold standard approach (i.e., TOPUP). Enhanced framewise distortion correction with MEDIC, without the requirement for field map collection, furthers the advantage of multi-echo over single-echo fMRI.
- assay: field survey / ecological data
- research focus: dimensionality reduction
- research focus: batch correction / integration
- approach: deep learning
- approach: statistical model
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- The Simultaneous Measurement of Reversed Phase-Encoding EPI in a Single fMRI Session: Evaluation of Geometric Distortion Correction in Submillimetre fMRI at 7T
Seong Dae Yun, Erhan Genç, … N. Jon Shah·bioRxiv·Sep 26, 2024
- Using synthetic MR images for field map-less distortion correction
David F. Montez, Andrew N. Van, … Nico U.F. Dosenbach·Developmental Cognitive NeurosciencePeer-reviewed·Mar 24, 2023
- EPI Distortion Correction is Easy and Useful, and You Should Use It: A case study with toddler data
V. Roopchansingh, J. J. French, … A. E. Thurm·bioRxiv·Sep 28, 2020
- Assessing methods for geometric distortion compensation in 7T gradient echo fMRI data
Michael‐Paul Schallmo, Kimberly B. Weldon, … Cheryl A. Olman·Human Brain MappingPeer-reviewed·Jun 22, 2021
- SynBOLD-DisCo: Synthetic BOLD images for distortion correction of fMRI without additional calibration scans
T. Yu, L. Y. Cai, … K. G. Schilling·bioRxiv·Sep 13, 2022
- Improved cortical boundary registration for locally distorted fMRI scans
Tim van Mourik, Peter J. Koopmans, David Gordon Norris·PLoS ONEPeer-reviewed·Nov 18, 2019