bioRxivBiophysicsPreprint
EPI Distortion Correction is Easy and Useful, and You Should Use It: A case study with toddler data
V. Roopchansingh, J. J. French, D. M. Nielson, R. C. Reynolds, D. R. Glen, P. D'Souza, P. A. Taylor, R. W. Cox, A. E. Thurm
Abstract
Task, resting state, and diffusion MRI data are usually acquired from subjects using echo-planar based imaging techniques. These techniques are highly susceptible to B0 homogeneity effects that result in geometric distortions in the reconstructed images. As researchers work to link the information from these scans back to various developmental stages, or to conditions and diseases in specific regions or structures of the brain, it becomes critical to have accurate correspondence between more geometrically distorted echo-planar images and less geometrically distorted anatomical images. A variety of techniques and tools have been developed to improve this correspondence. The basic premise behind most techniques used to mitigate geometric distortion is to acquire enough information to inform software tools how echo-planar images are warped, then have them undo that warping. Here, we investigate the application of two common methods: B0 correction, and reverse-polarity phase-encoding (or reverse blip) correction. We implement each of these in two separate, widely used software packages in the field: AFNI and FSL. We find that using either technique in either software package results in reduced geometric distortions in the EPI images. We discuss the practical implementations of these methods (e.g., increased scan and processing time). In general, however, both methods possess readily available data acquisition schemes, and are highly efficient to include in processing streams. Due to the overall data improvement, we strongly recommend that researchers include one of these methods in their standard protocols.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Assessing methods for geometric distortion compensation in 7T gradient echo fMRI data
Michael‐Paul Schallmo, Kimberly B. Weldon, … Cheryl A. Olman·Human Brain MappingPeer-reviewed·Jun 22, 2021
- Correction of susceptibility distortion in EPI: a semi-supervised approach with deep learning.
Antoine Legouhy, Mark S. Graham, … Hui Gary Zhang·bioRxiv·Jul 12, 2022
- Slice-direction geometric distortion evaluation and correction with reversed slice-select gradient acquisitions
Anna I. Blazejewska, Thomas Witzel, … Jon̈athan R. Polimeni·NeuroImagePeer-reviewed·Oct 23, 2022
- The Simultaneous Measurement of Reversed Phase-Encoding EPI in a Single fMRI Session: Evaluation of Geometric Distortion Correction in Submillimetre fMRI at 7T
Seong Dae Yun, Erhan Genç, … N. Jon Shah·bioRxiv·Sep 26, 2024
- Improved cortical boundary registration for locally distorted fMRI scans
Tim van Mourik, Peter J. Koopmans, David Gordon Norris·PLoS ONEPeer-reviewed·Nov 18, 2019
- Framewise multi-echo distortion correction for superior functional MRI
A. N. Van, D. F. Montez, … N. U. F. Dosenbach·bioRxiv·Nov 28, 2023