Improved cortical surface reconstruction using sub-millimeter resolution MPRAGE by image denoising
Q. Tian, N. Zaretskaya, Q. Fan, C. Ngamsombat, B. Bilgic, J. R. Polimeni, S. Y. Huang
Abstract
Automatic cerebral cortical surface reconstruction is a useful tool for cortical anatomy quantification, analysis and visualization. Recently, the Human Connectome Project and several studies have shown the advantages of using T1-weighted magnetic resonance (MR) images with sub-millimeter isotropic spatial resolution instead of the standard 1-millimeter isotropic resolution for improved accuracy of cortical surface positioning and thickness estimation. Nonetheless, sub-millimeter resolution images are noisy by nature and require averaging multiple repetitions to increase the signal-to-noise ratio for precisely delineating the cortical boundary. The prolonged acquisition time and potential motion artifacts pose significant barriers to the wide adoption of cortical surface reconstruction at sub-millimeter resolution for a broad range of neuroscientific and clinical applications. We address this challenge by evaluating the cortical surface reconstruction resulting from denoised single-repetition sub-millimeter T1-weighted images. We systematically characterized the effects of image denoising on empirical data acquired at 0.6 mm isotropic resolution using three classical denoising methods, including denoising convolutional neural network (DnCNN), block-matching and 4-dimensional filtering (BM4D) and adaptive optimized non-local means (AONLM). The denoised single-repetition images were found to be highly similar to 6-repetition averaged images, with a low whole-brain averaged mean absolute difference of [~]0.016, high whole-brain averaged peak signal-to-noise ratio of [~]33.5 dB and structural similarity index of 0.92, and minimal gray matter-white matter contrast loss (2% to 9%). The whole-brain mean absolute discrepancies in gray-white surface placement, gray-CSF surface placement and cortical thickness estimation were lower than 165 m, 155 m and 145 m--sufficiently accurate for most applications. The denoising performance is equivalent to averaging [~]2.5 repetitions of the data in terms of image similarity, and 1.6-2.2 repetitions in terms of the cortical surface placement accuracy. The scan-rescan precision of the cortical surface positioning and thickness estimation was lower than 170 m. Our unique dataset and systematic characterization support the use of denoising methods for improved cortical surface reconstruction sub-millimeter resolution.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- SurfNet: Reconstruction of Cortical Surfaces via Coupled Diffeomorphic Deformations
Hao Zheng, Hongming Li, Yong Fan A·IEEE Transactions on Medical ImagingPeer-reviewed·Jul 2, 2025
- Automatic Reconstruction of Cerebellar Cortex from Standard MRI Using Diffeomorphic Registration of a High-Resolution Template (ARCUS)
John G. Samuelsson, Bruce Robert Rosen, Matti Hämäläinen·bioRxiv·Nov 30, 2020
- A Framework for Cortical Layer Composition Analysis using Low Resolution T1 MRI Images
Ittai Shamir, Omri Tomer, … Yaniv Assaf·Brain Structure and FunctionPeer-reviewed·Feb 19, 2019
- Ultra-High Resolution TR-external EPIK with Deep Learning Image Reconstruction for Enhanced Characterisation of Cortical Depth-dependent Neural Activity
Seong Dae Yun, Jaejin Cho, … Nadim Jon Shah·bioRxiv·Feb 21, 2025
- Robust T1 MRI cortical surface pipeline for neonatal brain and systematic evaluation using multi-site MRI datasets
Mengting Liu, Claude Lepage, … Hosung Kim·Frontiers in NeurosciencePeer-reviewed·Mar 17, 2021
- Processing strategies for improving cortical thickness correspondence between low-field and high-field MRI in young people
Sunah Choi, Julia Shaw, … Maria Jalbrzikowski·Imaging NeurosciencePeer-reviewed·Jan 1, 2026