NeuroImageNeurosciencePeer-reviewed journal article
Simultaneous Estimation of Population Receptive Field and Hemodynamic Parameters from Single Point BOLD Responses using Metropolis-Hastings Sampling
Stanisław AdaszewskiiD, David Slater, Lester Melie‐GarcíaiD, Bogdan DraganskiiD, Piotr BogorodzkiiD
Abstract
We introduce a new approach to Bayesian pRF model estimation using Markov Chain Monte Carlo (MCMC) sampling for simultaneous estimation of pRF and hemodynamic parameters. To obtain high performance on commonly accessible hardware we present a novel heuristic consisting of interpolation between precomputed responses for predetermined stimuli and a large cross-section of receptive field parameters. We investigate the validity of the proposed approach with respect to MCMC convergence, tuning and biases. We compare different combinations of pRF - Compressive Spatial Summation (CSS), Dumoulin-Wandell (DW) and hemodynamic (5-parameter and 3-parameter Balloon-Windkessel) models within our framework with and without the usage of the new heuristic. We evaluate estimation consistency and log probability across models. We perform as well a comparison of one model with and without lookup table within the RStan framework using its No-U-Turn Sampler. We present accelerated computation of whole-ROI parameters for one subject. Finally, we discuss risks and limitations associated with the usage of the new heuristic as well as the means of resolving them. We found that the new algorithm is a valid sampling approach to joint pRF/hemodynamic parameter estimation and that it exhibits very high performance.
- Citations
- 11
- FWCI
- 1.47
- Field percentile
- top 19%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Hemodynamic modelling improves population receptive field estimates
Dietrich Samuel Schwarzkopf, Ecem Altan, … Catherine Morgan·bioRxiv·Nov 17, 2025
- Slice-sampled Bayesian PRF mapping
Silvan C. Quax, Thomas C. van Koppen, … Marcel A. J. van Gerven·bioRxiv·Dec 13, 2016
- Convex Optimized Population Receptive Field (CO-pRF) Mapping
David Slater, Lester Melie‐García, … Ferath Kherif·bioRxiv·Aug 3, 2017
- PINN-ing the Balloon: A Physically Informed Neural Network Modelling the Nonlinear Haemodynamic Response Function in MRI
Rodrigo H. Avaria, David Ortiz-Puerta, … Stéren Chabert·bioRxiv·Aug 25, 2026
- A Population Receptive Field Model of the Magnetoencephalography Response
Eline R. Kupers, Akhil Edadan, … Jonathan A. Winawer·NeuroImagePeer-reviewed·Sep 10, 2021
- BOLD response is more than just magnitude: improving detection sensitivity through capturing hemodynamic profiles
Gang Chen, Paul A. Taylor, … Simone P. Haller·NeuroImagePeer-reviewed·Jun 15, 2023