Ambient temperature TA has a strong impact on temperature based time since death estimation (TTDE). Frequently TA is lowered instantaneously at a time t0 from a start value TA0 to TA1 t0. We obtained promising results assuming Newtonian cooling for boxes filled with air, with heaps of clothes or even with books in two different experimental scenarios. Two different parameter estimators, (t0^, TA0^) forsingle quadruple temperature measurement and (t0*, TA0*) for N quadruple measurements were tested. Our results in a climate chamber were partially appropriate for TTDE input. A decline at time t0 from TA0 = 22.5{degrees}C {downarrow} TA1 = 14{degrees}C was reconstructed at t = t0 + 95min with relative deviations {rho}t0^ = 27% and {rho}TA0^ = 19% relative to t - t0 and TA0 - TA1 respectively, for N = 1 quadruple measurement with span {Delta}t = 50min. For N = 200 quadruple measurements in [t = t0 + 95min, t = t0 + 295min] we found {rho}t0^ = 5% and {rho}TA0^ = 11% with the same {Delta}t. Further research is necessary to guarantee applicability in routine casework. We will investigate more elaborate cooling models, estimation algorithms, and evaluation localization.