bioRxivPhysiologyPreprint
Revisiting the Humidity Ramp Protocol for Assessing Human Heat Tolerance Limits
Faming WangiD, Yi XuiD, Haojian WangiD, Min Cui, Hou Xue, Boan Wei, Xiong SheniD
Abstract
BackgroundHumidity ramp protocols are widely used to estimate human heat tolerance limits, yet reported critical environmental limits (CELs) vary markedly across studies. Whether this variability reflects true physiological differences or systematic methodological artifacts related to ramp design remains unresolved. MethodsWe combined first-order thermal modeling with controlled physiological trials to examine how ramp temporal structure (step dwell time) influences apparent rectal temperature (Tcr) inflection points. Twenty-six healthy young adults completed randomized trials at 42 {degrees}C under two protocols: an aggressive-ramp (30-min equilibration followed by humidity increases every 5 min) and a slow-ramp (4-h equilibration followed by hourly humidity increments). CELs derived from ramp protocols were further evaluated using prolonged fixed-condition exposures in independent cohorts (n=14 per sex). ResultsShort-step dwell times ({Delta}t/{tau} <<1) prevented rectal temperature from approaching its step-specific equilibrium, resulting in kinetically constrained, non-equilibrium dynamics and earlier Tcr inflection points. Consequently, aggressive-ramp protocols yielded substantially lower CELs than slow-ramp protocols in both sexes ({approx}3.5 {degrees}C difference). CELs derived from the slow ramp closely matched those obtained from prolonged fixed-condition exposures, whereas aggressive ramps misclassified physiologically compensable conditions as uncompensable. ConclusionRapid humidity increments systematically underestimate heat tolerance because environmental forcing outpaces physiological response kinetics. Accurate CEL determination requires either prolonged fixed-condition exposures (benchmark approach) or sufficiently slow ramps that allow near-equilibrium responses ({Delta}t/{tau} {gtrsim}0.3-0.5).
- Citations
- 3
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Critical Environmental Limits: Assessing the Limitations of Core Temperature Inflection Point (CTIP) and Biophysical Modeling
Faming Wang, Huijuan Xu, … Lijuan Wang·bioRxiv·Mar 21, 2025
- Mapping Human Survivability at Extreme Wet-Bulb Temperatures 32-35°C
Faming Wang, HW Wang, … Zhong Zhao·bioRxiv·Sep 22, 2025
- Critical Thermal maximum measurements and its biological relevance: the case of ants
C.-M. Leong, T. P. N. Tsang, B. Guenard·bioRxiv·Dec 9, 2020
- Heating tolerance of ectotherms is explained by temperature's non-linear influence on biological rates
J. D. Kong, J.-F. Arnoldi, … N. L. Payne·bioRxiv·Dec 6, 2022
- Five days of heat acclimation improves cardiovascular and thermoregulatory responses without altering renal stress biomarkers in endurance athletes
Daniel Snape, Barney G. Wainwright, … John O’Hara·PLoS ONEPeer-reviewed·Aug 11, 2026