Brain and BehaviorNeurosciencePeer-reviewed journal article
Lipid suppressed and tissue-fraction corrected metabolic distributions in human central brain structures using 2D 1H Magnetic Resonance Spectroscopic Imaging at 7 tesla
Alex A. BhogaliD, Tommy A.A. BroedersiD, Lisan M. MorsinkhofiD, Mirte Edens, S NassirpouriD, P ChangiD, Dennis W. J. KlompiD, Christiaan H. VinkersiD, Jannie P. WijneniD
Abstract
Magnetic resonance spectroscopic imaging (MRSI) has the potential to add a layer of understanding of the neurobiological mechanisms underlying brain diseases, disease progression, and treatment efficacy. Limitations related to metabolite fitting of low SNR data, signal variations due to partial volume effects, acquisition and extra-cranial lipid artefacts, along with clinically relevant aspects such as scan-time constraints, are among the factors that hinder the widespread implementation of in vivo MRSI. The aim of this work was to address these factors and to develop an acquisition, reconstruction and post-processing pipeline to derive lipid suppressed metabolite values based on Free Induction Decay (FID-MRSI) measurements made using a 7 tesla MR scanner. Anatomical images were used to perform high-resolution (1mm3) partial-volume correction to account for grey matter, white matter and cerebral-spinal fluid signal contributions. Implementation of automatic quality control thresholds and normalization of metabolic maps from 23 subjects to the MNI standard atlas facilitated the creation of high-resolution average metabolite maps of several clinically relevant metabolites in central brain regions, while accounting for macromolecular distributions. Reported metabolite values include glutamate, choline, (phospo)creatine, myo-inositol, glutathione, N-acetyl aspartyl glutamate(and glutamine) and N-acetyl aspartate. MNI-registered average metabolite maps facilitate group-based analysis; thus offering the possibility to mitigate uncertainty in variable MRSI.
- Citations
- 18
- FWCI
- 1.83
- Field percentile
- top 13%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Impacts of retrospective lipid suppression on metabolite quantification in preclinical proton MR spectroscopic imaging
Phan Tan Toi, Brayan Alves, … Cristina Cudalbu·bioRxiv·Sep 21, 2026
- Test-retest reproducibility of human brain multi-slice 1H FID-MRSI data at 9.4 T after optimization of lipid regularization, macromolecular model and spline baseline stiffness
Theresia Ziegs, Andrew Martin Wright, A Henning·bioRxiv·Feb 2, 2022
- MRSIPrep: A Standardized Post-Quantification Framework for Preprocessing Whole-Brain Magnetic Resonance Spectroscopic Imaging
Federico Lucchetti, Edgar Céléreau, … Paul Klauser·bioRxiv·Sep 16, 2026
- Achieving High-Resolution Whole-Brain Slab 1H-MRSI with Compressed-Sensing and Low-Rank Reconstruction at 7 Tesla
Antoine Klauser, Bernhard Strasser, … Ovidiu C. Andronesi·Journal of Magnetic ResonancePeer-reviewed·Aug 11, 2021
- Quantitative T1-relaxation corrected metabolite mapping of 12 metabolites in the human brain at 9.4 T
Andrew Martin Wright, Saipavitra Murali‐Manohar, A Henning·NeuroImagePeer-reviewed·Sep 1, 2022
- Whole-Brain High-Resolution Metabolite Mapping with 3D Compressed-Sensing-SENSE-LowRank 1H FID-MRSI
Antoine Klauser, Paul Klauser, … François Lazeyras·NMR in BiomedicinePeer-reviewed·Oct 1, 2021