Embedding wear assessment in musculoskeletal simulation: A proof-of-concept application to total hip arthroplasty
Abstract
Predicting wear in artificial joints requires integrating joint dynamics, contact mechanics and progressive surface evolution, yet these processes are often treated separately. In total hip arthroplasty (THA), finite-element approaches remain the reference standard, but they are computationally demanding and usually rely on boundary conditions from independent musculoskeletal (MSK) models, hindering consistent coupling and feedback between wear progression and movement dynamics. As a single-subject proof of concept, we present a computational framework that embeds wear estimation within forward MSK simulations through OpenSim-MATLAB integration. Contact variables are computed using an elastic-foundation formulation, and wear is updated through the Archard law, enabling cyclic prediction of contact mechanics and surface evolution within a single workflow at practical computational cost. The framework was evaluated in one subject with right THA during five activities of daily living and numerically benchmarked against finite-element simulations. A long-term walking analysis of 4 million cycles was also performed to assess geometry updating. Across tasks, peak contact pressures remained within 7% of finite-element predictions. Linear wear depth and volumetric loss showed maximum deviations of 16% and 13%, respectively. Accounting for progressive geometry changes yielded a maximum wear depth about 31% lower than linear extrapolation. These preliminary results support the framework's computational feasibility and numerical consistency for the tested case; nevertheless, multi-subject evaluation is required before broader predictive or clinical use.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- FWCI
- 0.00
- Field percentile
- top 19%
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Simulating Contact Using the Elastic Foundation Algorithm in OpenSim
M. W. Hast, B. G. Hanson, J. R. Baxter·bioRxiv·May 10, 2018
- Integration of a smooth mesh-based contact pressure model into tracking and predictive simulations
Mohanad Harba, Gil Serrancolí·bioRxiv·Sep 18, 2026
- How peak knee loads are affected by changing the mass of lower-limb body segments during walking
Delaney E. Miller, Ashley E. Brown, … Steven H. Collins·PLoS Computational BiologyPeer-reviewed·Sep 24, 2025
- A SENSORIZED 3D-PRINTED KNEE TEST RIG FOR EXPERIMENTAL VALIDATION OF PATELLAR TRACKING AND CONTACT SIMULATION AFTER TOTAL KNEE REPLACEMENT
Florian Michaud, Francisco Mouzo, … Javier Cuadrado·SensorsPeer-reviewed·May 10, 2024
- Can static optimization detect changes in peak medial knee contact forces induced by gait modifications?
J. M. Kaneda, K. A. Seagers, … S. L. Delp·bioRxiv·Jul 18, 2022
- Development and evaluation of a new methodology for Soft Tissue Artifact compensation in the lower limb
B. K. Lahkar, P.-Y. Rohan, … W. Skalli·bioRxiv·Feb 8, 2021