bioRxivMicrobiology
Humidity Reduces Rapid and Distant Airborne Dispersal of Viable Viral Particles in Classroom Settings
A. Skanata, F. Spagnolo, M. Metz, D. S. Smyth, J. J. Dennehy
Abstract
The transmission of airborne pathogens via aerosols is considered to be the main route through which a number of known and emerging respiratory diseases infect their hosts. It is therefore essential to quantify airborne transmission in closed spaces and determine the recommendations that should be implemented to minimize exposure to pathogens in built environments. We have developed a method to detect viable virus particles from aerosols by using an aerosolized bacteriophage Phi6 in combination with its host Pseudomonas phaseolicola, which when seeded on agar plates acts as a virus detector that can be placed at a range of distances away from an aerosol-generating source. Based on this method we present two striking results. (1) We consistently detected viable phage particles at distances of up to 18 feet away from the source within 15-minutes of exposure in a classroom equipped with a state of the art HVAC system. (2) Increasing the relative humidity beyond 40% significantly reduces dispersal. Our method can be used to quantify the exposure to pathogens at various distances from the source for different amounts of time, data which can be used to set safety standards for room capacity and to ascertain the efficacy of interventions that aim to reduce pathogen levels in closed spaces of specified sizes and intended uses. SummaryWe present a method to experimentally determine the exposure to airborne pathogens in closed spaces.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Risk of Infection Due to Airborne Virus in Classroom Environments Lacking Mechanical Ventilation
A. Goldblatt, M. J. Loccisano, … F. Spagnolo·bioRxiv·Dec 15, 2022
- Dependence of aerosol-borne influenza A virus infectivity on relative humidity and aerosol composition
Ghislain Motos, Aline Schaub, … Athanasios Nenes·Frontiers in MicrobiologyPeer-reviewed·Oct 16, 2024
- Effect of carrier droplet size and shape at different viral loads on virus stability during environmental drying
Sesan Nayak, Y.S. Mayya, … Mahesh Subramanyam Tirumkudulu·bioRxiv·Mar 27, 2025
- Reducing indoor particle exposure using mobile air purifiers - experimental and numerical analysis
A. Tobisch, L. Springsklee, … J. Niessner·bioRxiv·Jul 23, 2021
- Viability of MS2 and Phi6 Bacteriophages on Carpet and Dust
N. Nastasi, N. Renninger, … K. C. Dannemiller·bioRxiv·May 17, 2021
- Simulation of aerosol dispersion during medical examinations
Sebastian Falk, Sarina K. Mueller, … Michael Döllinger·Journal of Engineering and Science in Medical Diagnostics and TherapyPeer-reviewed·Mar 10, 2022