henhaobio
Sign in

PLoS ONENeurosciencePeer-reviewed journal article

The turning and barrier course reveals gait parameters for detecting freezing of gait and measuring the efficacy of deep brain stimulation

Johanna J. O’DayiD, Judy Syrkin‐Nikolau, Chioma M. AnidiiD, Łukasz KidzińskiiD, Scott L. DelpiD, Helen M Bronte-StewartiD

PDFDOIPreprint

Abstract

Freezing of gait (FOG) is a devastating motor symptom of Parkinsons disease that leads to falls, reduced mobility, and decreased quality of life. Reliably eliciting FOG has been difficult in the clinical setting, which has limited discovery of pathophysiology and/or documentation of the efficacy of treatments, such as different frequencies of subthalamic deep brain stimulation (STN DBS). In this study we validated an instrumented gait task, the turning and barrier course (TBC), with the international standard FOG questionnaire question 3 (FOG-Q3, r = 0.74, p < 0.001). The TBC is easily assembled and mimics real-life environments that elicit FOG. People with Parkinsons disease who experience FOG (freezers) spent more time freezing during the TBC compared to during forward walking (p = 0.007). Freezers also exhibited greater arrhythmicity during non-freezing gait when performing the TBC compared to forward walking (p = 0.006); this difference in gait arrhythmicity between tasks was not detected in non-freezers or controls. Freezers non-freezing gait was more arrhythmic than that of non-freezers or controls during all walking tasks (p < 0.05). A logistic regression model determined that a combination of gait arrhythmicity, stride time, shank angular range, and asymmetry had the greatest probability of classifying a step as FOG (area under receiver operating characteristic curve = 0.754). Freezers percent time freezing and non-freezing gait arrhythmicity decreased, and their shank angular velocity increased in the TBC during both 60 Hz and 140 Hz STN DBS (p < 0.05) to non-freezer values. The TBC is a standardized tool for eliciting FOG and demonstrating the efficacy of 60 Hz and 140 Hz STN DBS for gait impairment and FOG. The TBC revealed gait parameters that differentiated freezers from non-freezers and best predicted FOG; these may serve as relevant control variables for closed loop neurostimulation for FOG in Parkinsons disease.

Citations
44
FWCI
10.89
Field percentile
top 1%

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.