bioRxivNeurosciencePreprint
In vivo human neurite exchange imaging (NEXI) at 500 mT/m diffusion gradients
Kwok‐Shing ChaniD, Yixin MaiD, Hansol LeeiD, José P. MarquesiD, Jonas Lynge OleseniD, Santiago CoelhoiD, Dmitry S. NovikoviD, Sune Nørhøj JesperseniD, Susie Y. HuangiD, Hong‐Hsi LeeiD
Abstract
Evaluating tissue microstructure and membrane integrity in the living human brain through diffusion-water exchange imaging is challenging due to requirements for a high signal-to-noise ratio and short diffusion times dictated by relatively fast exchange processes. The goal of this work was to demonstrate the feasibility of in vivo imaging of tissue micro-geometries and water exchange within the brain gray matter using the state-of-the-art Connectome 2.0 scanner equipped with an ultra-high-performance gradient system (maximum gradient strength=500 mT/m, maximum slew rate=600 T/m/s). We performed diffusion MRI measurements in 15 healthy volunteers at multiple diffusion times (13-30 ms) and b-values up to 17.5 ms/m2. The anisotropic Karger model was applied to estimate the exchange time between intra-neurite and extracellular water in gray matter. The estimated exchange time across the cortical ribbon was around (median{+/-}interquartile range) 13{+/-}8 ms on Connectome 2.0, substantially faster than that measured using an imaging protocol compatible with Connectome 1.0-alike systems on the same cohort. Our investigation suggested that the NEXI exchange time estimation using a Connectome 1.0 compatible protocol was more prone to residual noise floor biases due to the small time-dependent signal contrasts across diffusion times when the exchange is fast ([≤]20 ms). Furthermore, spatial variation of exchange time was observed across the cortex, where the motor cortex, somatosensory cortex and visual cortex exhibit longer exchange times compared to other cortical regions. Non-linear fitting for the anisotropic Karger model was accelerated 100 times using a GPU-based pipeline compared to the conventional CPU-based approach. This study highlighted the importance of the chosen diffusion times and measures to address Rician noise in dMRI data, which can have a substantial impact on the estimated NEXI exchange time and require extra attention when comparing NEXI results between various hardware setups. Highlights- The Connectome 2.0 scanner equipped with 500 mT/m gradients enables high-sensitivity diffusion MRI for imaging exchange times in vivo - The global exchange time across the living human cortex was estimated to be about 13 ms on Connectome 2.0, faster than measured using a protocol compatible to Connectome 1.0 - Spatially varying exchange times were observed across the cortex - A GPU-accelerated tool was developed to speed up parameter estimation by 100 times - The narrow pulse approximation used in neurite exchange imaging does not affect estimation performance in high gradient performance MRI systems
- Citations
- 1
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Human gray matter microstructure mapped using Neurite Exchange Imaging (NEXI) on a clinical scanner
Quentin Uhl, Tommaso Pavan, … Ileana Jelescu·Imaging NeurosciencePeer-reviewed·Jan 1, 2025
- Validating Neurite EXchange Imaging (NEXI) using diffusion Monte Carlo simulations in realistic numerical gray matter substrates
Rita Oliveira, Jasmine Nguyen‐Duc, … Ileana Jelescu·bioRxiv·Feb 12, 2026
- Multi-dimensional diffusion MRI at ultra-high gradient strength for mapping axonal architecture and microstructure in the primate brain
Ting Gong, Chiara Maffei, … Anastasia Yendiki·bioRxiv·Mar 27, 2026
- Comparative Systematic Analysis of Gray Matter BiophysicalModels on a Public Dataset
Santiago Mezzano, Quentin Uhl, … Ileana Jelescu·Magnetic Resonance in MedicinePeer-reviewed·Jul 16, 2026
- High-fidelity, high-spatial-resolution diffusion MRI of the ex-vivo whole human brain on the 3T Connectom scanner using structured low-rank EPI ghost correction
Gabriel Ramos‐Llordén, Rodrigo A. Lobos, … Susie Y. Huang·bioRxiv·Aug 1, 2021
- Validation of diffusion and exchange imaging biomarkers via simultaneous real-time NMR and optical microscopy
Rea Ravin, Nathan H. Williamson, … Peter J. Basser·bioRxiv·Jul 21, 2026