bioRxivBiophysics
A workflow for sizing oligomeric biomolecules based on cryo single molecule localization microscopy
M. C. Schneider, R. Telschow, G. Mercier, M. Lopez-Martinez, O. Scherzer, G. Schütz
Abstract
Single molecule localization microscopy (SMLM) has enormous potential for resolving subcellular structures below the diffraction limit of light microscopy: Localization precision in the low digit nanometer regime has been shown to be achievable. In order to record localization microscopy data, however, sample fixation is inevitable to prevent molecular motion during the rather long recording times of minutes up to hours. Eventually, it turns out that preservation of the samples ultrastructure during fixation becomes the limiting factor. We propose here a workflow for data analysis, which is based on SMLM performed at cryogenic temperatures. Since molecular dipoles of the fluorophores are fixed at low temperatures, such an approach offers the possibility to use the orientation of the dipole as an additional information for image analysis. In particular, assignment of localizations to individual dye molecules becomes possible with high reliability. We quantitatively characterized the new approach based on the analysis of simulated oligomeric structures. Side lengths can be determined with a relative error of less than 1% for tetramers with a nominal side length of 5 nm, even if the assumed localization precision for single molecules is more than 2 nm.
- assay: fluorescence / live-cell microscopy
- research focus: cell type annotation
- approach: microscopy & imaging analysis
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- A workflow for the identification of oligomeric structures on tilted sample planes in Cryo-SMLM
Yakun Dong, Zheyi Yang, … Gerhard J. Schütz·OpticsPeer-reviewed·Aug 3, 2026
- Improving localization precision via restricting biomolecule confined stochastic motion in SMLM
- Identification and calibration of ultrabright localizations to eliminate quantification error in SMLM
- Orientation Single Molecule Localization Microscopy (oSMLM) for Decoding Orientation of Single Molecule
P. Joshi, P. P. Mondal·bioRxiv·Jun 27, 2023
- About samples, giving examples: Optimized Single Molecule Localization Microscopy
A. Jimenez, K. Friedl, C. Leterrier·bioRxiv·May 11, 2019
- Single Molecule Light Field Microscopy
R. R. Sims, S. Abdul Rehman, … K. O'Holleran·bioRxiv·May 20, 2020