BioelectromagneticsPhysiologyPeer-reviewed journal article
Action Potential Threshold Variability for Different Electrostimulation Models and the Impact on Occupational Exposure Limit Values
Florian SoykaiD, Thomas TarnaudiD, Carsten Alteköster, Ruben SchoetersiD, Tom PlovieiD, Wout JosephiD, Emmeric TangheiD
Abstract
Occupational exposure limit values (ELVs) for body internal electric fields can be derived from thresholds for action potential generation. These thresholds can be calculated with electrostimulation models. The spatially extended nonlinear node model (SENN) is often used to determine such thresholds. An important part of these models are the membrane channel dynamics describing the ionic transmembrane currents. This work shows how ELVs change significantly with different ion channel dynamics (up to a factor of 22). Furthermore, two more detailed double-cable models by Gaines et al. (MRG-Sensory and MRG-Motor) are also considered in this work. Thresholds calculated with the SENN model (with Frankenhaeuser-Huxley membrane channel dynamics) and the MRG models are compared for frequencies between 1 Hz and 100 kHz and temperatures between 22 {degrees}C and 37 {degrees}C. Results show that MRG thresholds are lower than SENN thresholds. In the context of occupational ELVs, using the double cable model would lead to approximately ten times lower limit values. Therefore, future exposure guidelines should take the influence of different electrostimulation models into account when deriving ELVs. HighlightsO_LIDifferent membrane channel dynamics change derived exposure limit values by more than one order of magnitude. C_LIO_LIDouble-cable models result in a reduction of derived exposure limit values by one order of magnitude. C_LIO_LILower temperatures reduce the action potential thresholds at frequencies below 300 Hz. C_LI
- Citations
- 5
- FWCI
- 0.69
- Field percentile
- top 35%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Evaluation of Neuronal Activation Thresholds for Low-Frequency Electromagnetic Exposure Using Morphologically Realistic Neuron Models
Joaquin Gazquez, Carolina Camacho Cadena, … Emmeric Tanghe·Physics in Medicine and BiologyPeer-reviewed·Sep 4, 2026
- Individual versus fixed parametrization of an electrocutaneous warning signal during manual work tasks
Eva‐Maria Dölker, Rami Farouk, … Jens Haueisen·bioRxiv·Sep 23, 2026
- Single pointwise samples of electric field on a neuron model cannot predict activation threshold by brain stimulation
Boshuo Wang, Minhaj A. Hussain, … Angel V. Peterchev·Brain stimulationPeer-reviewed·Sep 1, 2025
- Dynamical regimes of excitable cells under pulsed electric fields: From excitation to electroporation
MD RASHID ALI FARIDI, Rohit Manchanda, Rochish Thaokar·bioRxiv·Oct 28, 2026
- Modeling implanted metals in electrical stimulation applications
B. Mercadal, R. Salvador, … G. Ruffini·bioRxiv·Dec 4, 2021
- Threshold Electric Skin Sensitivity Fluctuations in Pregnancy, Labor and Puerperium.
Charles Boris Cernoch Rossmann, William von Taaffe, Cosima von Taaffe·BioelectricityPeer-reviewed·Dec 12, 2019