eNeuroNeurosciencePeer-reviewed journal article
The Listening Zone of Human Electrocorticographic Field Potential Recordings
Meredith J. McCartyiD, Oscar WoolnoughiD, John C. MosheriD, John P. SeymouriD, Nitin TandoniD
Abstract
Intracranial electroencephalographic (icEEG) recordings provide invaluable insights into neural dynamics in humans due to their unmatched spatiotemporal resolution. Yet, such recordings reflect the combined activity of multiple underlying generators, confounding the ability to resolve spatially distinct neural sources. To empirically quantify the listening zone of icEEG recordings, we computed the correlations between signals as a function of distance (expressed as full width at half maximum; FWHM) between 8,752 recording sites in 71 patients implanted with either subdural electrodes (SDE), stereo-encephalography electrodes (sEEG), or high-density sEEG electrodes. As expected, for both SDE and sEEG electrodes, higher frequency signals exhibited a sharper fall off relative to lower frequency signals. For broadband high gamma (BHG) activity, the mean FWHM of SDEs (6.6 {+/-} 2.5 mm) and sEEGs in gray matter (7.14 {+/-} 1.7 mm) was not significantly different, however the FWHM for low frequencies recorded by sEEGs was 2.45 mm smaller than SDEs. White matter sEEG electrodes showed much lower power for frequencies 17 to 200 Hz (q < 0.01) and a much broader decay (11.3 {+/-} 3.2 mm) than gray matter electrodes (7.14 {+/-} 1.7 mm). The use of a bipolar referencing scheme significantly lowered FWHM for sEEG electrodes, as compared with a white matter reference or a common average reference. These results outline the influence of array design, spectral bands, and referencing schema on local field potential recordings and source localization in icEEG recordings in humans. The metrics we derive have immediate relevance to the analysis and interpretation of both cognitive and epileptic data.
- organism: human
- assay: electronic health records
- research focus: spatial domain detection
- approach: statistical model
- Citations
- 40
- FWCI
- 4.00
- Field percentile
- top 5%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Low and high frequency intracranial neural signals match in the human associative cortex
Corentin Jacques, Jacques Jonas, … Bruno Rossion·eLifePeer-reviewed·Aug 19, 2022
- Data-driven re-referencing of intracranial EEG based on independent component analysis (ICA)
Sebastian Michelmann, Matthias Sebastian Treder, … Simon Hanslmayr·Journal of Neuroscience MethodsPeer-reviewed·Jun 27, 2018
- Long range, high-gamma phase coherence in the human brain during overt and covert speech
Taufik A. Valiante, Bojan Garic·bioRxiv·Jan 23, 2021
- Topography, Spectral Characteristics, and Extra-to-Intracranial Propagation Pathways of EMG
Jacob Lahr, L.D.J. Fiederer, … Tonio Ball A·bioRxiv·Oct 17, 2019
- How well does electrical source imaging reconstruct neural time series? Evidence from simultaneous scalp and intracranial EEG recordings
Maria Dimou, Steven Beumer, … Nicolas Roehri·bioRxiv·Oct 27, 2026
- The Spatial Reach of Neuronal Coherence and Spike-field Coupling across the Human Neocortex
John C. Myers, Elliot H. Smith, … Sameer Anil Sheth·Journal of NeurosciencePeer-reviewed·Jul 5, 2022