Automatic Assessment of Human Gastric Motility and Emptying from Dynamic 3D Magnetic Resonance Imaging
K.-H. Lu, Z. Liu, D. Jaffey, J. Wo, K. Mosier, J. Cao, X. Wang, T. L. Powley
Abstract
BackgroundTime-sequenced magnetic resonance imaging (MRI) of the stomach is an emerging technique for non-invasive assessment of gastric emptying and motility. However, an automated and systematic image processing pipeline for analyzing dynamic 3D (i.e., 4D) gastric MRI data is not yet available. This study introduces an MRI protocol for imaging the stomach with high spatiotemporal isotropic resolution and provides an integrated pipeline for assessing gastric emptying and motility simultaneously. MethodsDiet contrast-enhanced MRI images were acquired from seventeen healthy humans after they consumed a naturalistic contrast meal. An automated image processing pipeline was developed to correct for respiratory motion, to segment and compartmentalize the lumen-enhanced stomach, to quantify total gastric and compartmental emptying, and to compute and visualize gastric motility on the surface of the stomach. Key ResultsThe gastric segmentation reached an accuracy of 91.10{+/-}0.43% with the Type-I error and Type-II error being 0.11{+/-}0.01% and 0.22{+/-}0.01%, respectively. Gastric volume decreased 34.64{+/-}2.8% over 1 hour where the emptying followed a linear-exponential pattern. The gastric motility showed peristaltic patterns with a median = 4 wave-fronts (range 3 - 6) and a mean frequency of 3.09{+/-}0.07 cycles per minute (CPM). Further, the contractile amplitude was stronger in the antrum than in the corpus (antrum vs. corpus: 5.18{+/-}0.24 vs. 3.30{+/-}0.16 mm; p < .001). Conclusions & InferencesThe automated, streamlined software can process dynamic 3D MRI images and produce comprehensive and personalized profiles of gastric motility and emptying. This software will facilitate the application of MRI for monitoring gastric dynamics in research and clinical settings.
02 /Specification & Classification
Click any tag to browse matching papers- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Dynamic Magnetic Resonance Imaging of Whole-Stomach Motility in Rats
Xiaokai Wang, Ulrich M. Scheven, Zhongming Liu·NMR in BiomedicinePeer-reviewed·Sep 9, 2025
- Surface-based Characterization of Gastric Anatomy and Motility using Magnetic Resonance Imaging and Neural Ordinary Differential Equation
- Magnetic Resonance Imaging of Gastric Motility in Conscious Rats
Xiaokai Wang, Fatimah Alkaabi, … Zhongming Liu·Neurogastroenterology & MotilityPeer-reviewed·Dec 31, 2024
- Vagus Nerve Stimulation Promotes Gastric Emptying by Increasing Pyloric Opening Measured with Magnetic Resonance Imaging
- Towards Passive Dietary Monitoring: Dilated CNN-Based Meal Detection Using Ambulatory High-Resolution Electrogastrography
Belinda Chen, Sandya Subramanian·bioRxiv·Jun 17, 2026
- Optimizing non-invasive assessment of gastric activity: a fully automated channel-wise pipeline for multi-electrode electrogastrography
Alessandro Iannone, Maria Serena Panasiti, … Stefania Della Penna·bioRxiv·Nov 3, 2026