Personalization of Closed-Chain Shoulder Models Yields High Kinematic Accuracy for Multiple Motions
Claire V. HammondiD, Heath B. HenningeriD, Benjamin Jon FreglyiD, Jonathan Adam GustafsoniD
Abstract
The shoulder joint complex is prone to musculoskeletal issues, such as rotator cuff-related pain, which affect two-thirds of adults and often result in suboptimal treatment outcomes. Current musculoskeletal models used to understand shoulder biomechanics are limited by challenges in personalization, inaccuracies in predicting joint and muscle loads, and an inability to simulate anatomically accurate motions. To address these deficiencies, we developed a novel, personalized modeling framework capable of calibrating subject-specific joint centers and functional axes for the shoulder complex. Leveraging in vivo biplane fluoroscopy data and the recent Joint Model Personalization Tool from the Neuromusculoskeletal Modeling Pipeline, we optimized joint parameters and body scale factors for shoulder models with varying degrees of freedom (DOFs). We initially created and tested open-chain scapula-only models (3DOF, 4DOF, and 5DOF) and found that increasing DOFs improved accuracy, with the 5 DOF model yielding the lowest marker distance errors (average = 0.8 mm, maximum = 5.2 mm) as compared to biplane fluorscopy data of the scapula across eight movement trials. We subsequently created closed-chain shoulder models incorporating scapula, clavicle, and humerus bodies. We found closed-chain shoulder models with 5 DOFs for the scapula achieved the highest accuracy (average = 0.9 mm, maximum = 5.7 mm) and showed consistent performance across subjects (n=3) in leave-one-out cross-validation tests (average marker distance errors = 1.0-1.4 mm). This framework minimizes errors in joint kinematics and provides a foundation for future models incorporating personalized musculature and advanced simulations, enhancing its potential clinical utility for rehabilitation and surgical planning.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 3
- FWCI
- 2.51
- Field percentile
- top 11%
- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Personalizing a computational upper body model improves kinematic tracking in high range-of-motion arm movements
Jennifer N. Maier, Nicholas A. Bianco, … Scott L. Delp·Journal of BiomechanicsPeer-reviewed·Oct 11, 2024
- Functional and Structural Moment Arm Validation for Musculoskeletal Models: A Study of the Human Forearm and Hand
Matthew T. Boots, Russell L. Hardesty, … Sergiy Yakovenko·bioRxiv·May 29, 2020
- Automatic Generation of Personalised Skeletal Models of the Lower Limb from Three-Dimensional Bone Geometries
L. Modenese, J.-B. Renault·bioRxiv·Jun 23, 2020
- An innovative 2D-mesh model to improve deltoid moment arms, muscle forces and glenohumeral joint reaction force estimations
Marta Strzelczak, Margaux Peixoto, … Nicola Hagemeister·bioRxiv·Sep 30, 2022
- Automated muscle path calibration with gradient-specified optimization based on moment arm
Ziyu Chen, Tingli Hu, … David W. Franklin·IEEE Transactions on Biomedical EngineeringPeer-reviewed·Oct 13, 2025
- A Workflow to Create Personalised Musculoskeletal Models Based on Magnetic Resonance Images
Ekaterina Stansfield, Willi Koller, … Hans Kainz·bioRxiv·Jul 23, 2025