Sign in
BioinformaticsbioRxiv
Preprint

Cadence: A Benchmark Evaluation of the Narrative Velocity Framework for Next Clinical Event Prediction in MIMIC-IV

Amir RouhollahiiD, Farhad R. NezamiiD

Abstract

ObjectiveHow structured clinical features and cluster-semantic embeddings interact under self-distillation in EHR prediction models is unknown. Existing approaches treat these sources separately (gradient-boosted trees exploit tabular features while sequence models process text), and their interaction under self-distillation regularisation remains uncharacterised. We introduce the Narrative Velocity (NV) framework and evaluate this interaction in a 7-model benchmark. Materials and MethodsCadence is a [~]5.86M-parameter residual multilayer perceptron (MLP) combining structured EHR features with frozen PubMedBERT embeddings of cluster-label strings under born-again self-distillation from a prior Cadence checkpoint (seed-42 teacher; [1]). Cadence is benchmarked against six comparators on MIMIC-IV v3.1 with dual-sex TRIPOD+AI reporting (5 student seeds for Cadence; 2-3 seeds for baselines). ResultsAt full-cohort scale, Cadence achieves 38.04 {+/-} 0.04% male and 35.66 {+/-} 0.04% female top-1 accuracy, exceeding the strongest non-neural baseline (XGBoost-2420, trained on the identical 2,420-dimensional input) by +1.35 pp male and +0.82 pp female (paired t-test on shared seeds 42-44: t(2) = 69.06, p = 2.10 x 10-4 male; t(2) = 25.32, p = 1.56 x 10-3 female). On time-to-next-event regression Cadence lowers MAE by 7.68 d male and 7.30 d female versus XGBoost-2420; FT-Transformer attains the lowest absolute MAE at full scale (27.58 d male, 36.63 d female), revealing a classification-regression trade-off across model families. A controlled 2 x 2 random-vector ablation isolates the self-distillation-embedding interaction at +0.49 pp top-1 (95% CI [0.35, 0.64] pp; bootstrap, n = 10,000 resamples; 3-teacher-seed mean +0.513 {+/-} 0.010 pp) under a matched-dimensionality null. A 3-teacher-seed validation (multi_teacher_02) confirms the interaction is robust to teacher-seed identity (per-seed values +0.525, +0.509, +0.507 pp; mean +0.513 {+/-} 0.010 pp). Cadence achieves the best Brier score among evaluated models (0.774 male / 0.798 female) but its raw probabilities are systematically miscalibrated (ECE 0.077 vs. XGBoost-884s 0.010); after a single scalar temperature scaling step (T * {approx} 0.81), ECE drops to {approx}0.028 while Brier remains best. On a small (n = 1,120 patients, 39,120 events) external OCR-extracted BWH cohort, Cadence ranked 3rd of 7 models with three confounded sources of error (institutional shift, OCR noise, centroid mapping); we therefore report this as a generalisation probe rather than a definitive external validation. At the longer h30 evaluation horizon Cadences MAE advantage reverses (47.35 d versus XGBoost 45.06 d), reflecting the absence of a matched-horizon self-distillation teacher. DiscussionThe 2 x 2 random-vector ablation confirms that the self-distillation gain on PubMedBERT embeddings (+0.78 pp) exceeds that on matched-dimensionality random vectors (+0.29 pp) by +0.49 pp, isolating the interaction to semantic content rather than feature dimensionality. The factorial decomposition (+0.49-0.51 pp interaction) and the sequential pipeline-level decomposition (Supplementary Table S3) are complementary triangulations under different reference frames and are not directly additive. ConclusionThis 7-model benchmark establishes a dual-sex, dual-metric, cross-institutional reference for next clinical event prediction under the TRIPOD+AI reporting framework. These results characterise discrimination and calibration on a single retrospective cohort; prospective evaluation, decision-curve analysis, and harm-benefit assessment are required before clinical deployment.

PDFDOI

02 /Specification & Classification

Click any tag to browse matching papers

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISBeaulieu‐Jo '17Liu '20Liu '20Tuerhanbayi '26McWilliams '19Rezaee '19
55% semantic matchBioinformatics
Brett K. Beaulieu‐Jones, Patryk Orzechowski, Jason H. Moore·Pacific Symposium on Biocomputing (PSB)·Nov 17, 2017· 56 citations