An adversarial approach to guide the selection of preprocessing pipelines for ERP studies
Daniele ScanziiD, Dylan A. Taylor, K. Manon McnairiD, Rohan O. C. KingiD, Carley Ann BraddockiD, Paul Michael CorballisiD
Abstract
Electroencephalography (EEG) data are inherently contaminated by non-neuronal noise, including eye movements, muscle activity, cardiac signals, electrical interference, and technical issues such as poorly connected electrodes. Preprocessing to remove these artefacts is essential, yet the optimal method remains unclear due to the vast number of available techniques, their combinatorial use in pipelines, and adjustable parameters. Consequently, most studies adopt ad hoc preprocessing strategies based on dataset characteristics, study goals, and researcher expertise, with little justification for their choices. Such variability can influence downstream results, potentially determining whether effects are detected, and introduces risks of questionable analytical practices. Here, we present a method to objectively evaluate and compare preprocessing pipelines. Our approach uses realistically simulated signals injected into real EEG data as "ground truth", enabling the assessment of a pipelines ability to remove noise without distorting neuronal signals. This evaluation is independent of the studys main analyses, ensuring that pipeline selection does not bias results. By applying this procedure, researchers can select preprocessing strategies that maximize signal-to-noise ratio while maintaining the integrity of the neural signal, improving both reproducibility and interpretability of EEG studies. Although the data presented here focuses on processing and analysis most relevant for ERP research, the method can be flexibly expanded to other types of analyses or signals.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- How Sensitive are EEG Results to Preprocessing Methods: A Benchmarking Study
Kay A. Robbins, Jonathan Touryan, … Nima Bigdely-Shamlo·IEEE Transactions on Neural Systems and Rehabilitation EngineeringPeer-reviewed·Mar 26, 2020
- EEG is better left alone
Arnaud Delorme A·Scientific ReportsPeer-reviewed·Feb 9, 2023
- EEG is better when cleaning effectively targets artifacts
Neil Wayne Bailey, Aron T. Hill, … Paul Bernard Fitzgerald·Clinical NeurophysiologyPeer-reviewed·Oct 10, 2025
- Introducing RELAX (the Reduction of Electroencephalographic Artifacts): A fully automated pre-processing pipeline for cleaning EEG data - Part 2: Application to Event-Related Potentials
Neil Wayne Bailey, Aron T. Hill, … Paul Bernard Fitzgerald·Clinical NeurophysiologyPeer-reviewed·Feb 13, 2023
- The HAPPE plus Event-Related (HAPPE+ER) Software: A Standardized Processing Pipeline for Event-Related Potential Analyses
A.D. Monachino, Kelsie Lynn Lopez, … Laurel Joy Gabard-Durnam·Developmental Cognitive NeurosciencePeer-reviewed·Jul 19, 2022
- AUTOMAGIC: Standardized Preprocessing of Big EEG Data
Andreas Pedroni, Amirreza Bahreini, Nicolas Langer·NeuroImagePeer-reviewed·Jun 21, 2019