Soft, 3D printed muscle ultrasound phantom with structurally tunable B-mode echo intensity
Samuel D Gillespie, Caralyn Paige CollinsiD, Eric Jon PerreaultiD, Cheng SuniD, Oluwaseyi O. BaloguniD, Wendy M. MurrayiD
- Citations
- 1
Abstract
OBJECTIVESImaging phantoms for training and validation are vital to improving the performance and adoption of ultrasound imaging modalities in clinical and pre-clinical applications, and the goal of this study was to assess the viability of 3D printed muscle ultrasound phantoms to meet this need. METHODSWe used a soft stereolithography resin to 3D print phantoms that mimicked the fascicle- and perimysium-scale structure of skeletal muscle and compared the long axis B-mode imaging quality and pattern of the phantom to that of healthy, adult Biceps brachii. We used a pulse-echo, time-of-flight method to measure the acoustic impedance of the resin for comparison to skeletal muscle and common soft tissue mimicking materials. We analyzed the echo intensity (EI) of muscle images to establish a physiological range and compared the EI of different phantom designs to assess the ability to control imaging brightness through structural modification. RESULTSA linear, striated hyper-/hypo-echoic B-mode imaging pattern mimicking long axis Biceps brachii muscle images was achieved with two 3D structure paradigms, rod and honeycomb. Acoustic impedance of Elastic 50A resin is higher than skeletal muscle in bulk, but appears suitable for use in a 3D structured phantom. EI measured in the Biceps images were found to vary both within and across images with an overall mean {+/-} SD of 87 {+/-}13 AU. EI measured in honeycomb phantoms (55 {+/-}15 AU) was higher than in rod phantoms (42 {+/-}13 AU), and a latticed honeycomb further increased EI (90 {+/-}11 AU). CONCLUSIONSThis study serves as proof-of-concept for soft, 3D printed phantoms that replicate the characteristic muscle ultrasound imaging pattern with the ability to tune clinically relevant EI values via structural design.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- High Resolution Acoustic Mapping of Gelatin-Based Soft Tissue Phantoms
H. Badawe, P. Raad, M. Khraiche·bioRxiv·May 10, 2023
- Validity of freehand three-dimensional ultrasound system in measurement of three-dimensional surface shape of shoulder muscles
J. Umehara, N. Fukuda, … M. Hirashima·bioRxiv·Nov 18, 2021
- Three-dimensional tissue strain measurement using a row-column array during biaxial testing of excised ventricular myocardium
Xavier Navy, Zhiyu Sheng, … John M. Cormack·Ultrasound in Medicine & BiologyPeer-reviewed·Jun 12, 2025
- High Volume Rate 3-D Ultrasound Imaging Using Fast-Tilting and Redirecting Reflectors
Z. Dong, S. Li, … P. Song·IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency ControlPeer-reviewed·Aug 1, 2023
- Electrical properties, accuracy, and multi-day performance of gelatine phantoms for electrophysiology
A. Y. Owda, A. J. Casson·bioRxiv·May 30, 2020
- A multimodal brain phantom for noninvasive neuromodulation
John LaRocco·bioRxiv·Oct 13, 2025