bioRxivPhysiology
Denoising physiological data collected during multi-band, multi-echo EPI sequences
K. L. Bottenhorn, T. Salo, M. C. Riedel, M. T. Sutherland, J. L. Robinson, E. D. Musser, A. R. Laird
Abstract
Collecting physiological data during fMRI experiments can improve fMRI data cleaning and contribute to our understanding of psychophysiological processes; however, these recordings are frequently fraught with artifacts from the MRI pulse sequence. Here, we assess data from BIOPAC Systems, Inc., one of the more widely-used manufacturers of physiological monitoring equipment, and evaluate their recommendations for filtering such artifacts from electrocardiogram and electrodermal activity data collected during single-band, single-echo fMRI sequences and extend these recommendations to address artifacts associated with multiband, multi-echo fMRI sequences. While the magnitude and frequencies of artifacts differ with these aspects of pulse sequences, their effects can be mitigated via application of digital filters incorporating slice collection, multiband factor, and repetition time. The implementation of these filters is provided both in interactive online notebooks and an open source denoising tool.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Unsupervised physiological noise correction of fMRI data using phase and magnitude information (PREPAIR)
David Bancelin, Beata Bachrátá, … Simon Robinson·bioRxiv·Feb 18, 2022
- Comparing the efficacy of data-driven denoising methods for a multi-echo fMRI acquisition at 7T
Abraham B. Beckers, Gerhard S. Drenthen, … Dániel Keszthelyi·NeuroImagePeer-reviewed·Sep 3, 2023
- Data-driven beamforming techniques to attenuate ballistocardiogram (BCG) artefacts in EEG-fMRI without detecting cardiac pulses in electrocardiography (ECG) recordings
Makoto Uji, Nathan E. Cross, … Christophe Grova·Human Brain MappingPeer-reviewed·Jun 8, 2021
- Safety and data quality of EEG recorded simultaneously with multi-band fMRI
Maximillian K. Egan, Ryan J. Larsen, … Sepideh Sadaghiani·PLoS ONEPeer-reviewed·Jul 2, 2021
- A lightweight, physics-based, sensor-fusion filter for real-time EEG denoising and improved downstream AI classification
Jack-Michael Wesierski, Nicholas Rodriguez·bioRxiv·Sep 24, 2025
- Correction of respiratory artifacts in MRI head motion estimates
Damien A. Fair, Óscar Miranda-Domínguez, … Nico U.F. Dosenbach·NeuroImagePeer-reviewed·Nov 25, 2019