Comparing the efficacy of data-driven denoising methods for a multi-echo fMRI acquisition at 7T
Abraham B. BeckersiD, Gerhard S. DrentheniD, Jacobus F.A. JanseniD, Walter H. BackesiD, Benedikt Andreas PoseriD, Dániel KeszthelyiiD
Abstract
In functional magnetic resonance imaging (fMRI) of the brain the signal is dominated by (physiological) noise. Imaging at ultrahigh field strength is becoming increasingly popular as it offers increased spatial accuracy. The latter is of particular benefit in brainstem neuroimaging given the small cross-sectional area of most nuclei. Physiological noise scales with field strength in fMRI acquisitions, however. Although this problem is in part solved by decreasing voxel size, it is clear that adequate physiological denoising is of utmost importance in brainstem-focused fMRI experiments. Multi-echo sequences have been reported to facilitate highly effective denoising through TE-dependence of Blood Oxygen Level Dependent (BOLD) signals, in a denoising method referred to as multi-echo independent component analysis (ME-ICA). It has not been explored previously how ME-ICA compares to other data-driven denoising approaches at ultrahigh field strength. In the current study, we compared the efficacy of several denoising methods, including anatomical component based correction (aCompCor), Automatic Removal of Motion Artifacts (ICA-AROMA), ME-ICA, and a combination of ME-ICA and aCompCor. We assessed several data quality metrics, including temporal signal-to-noise ratio (tSNR), delta variation signal (DVARS) and spectral density of the global signal. Moreover, we looked at the ability of each method to uncouple the global signal and respiration. In line with previous reports at lower field strengths, we demonstrate that after applying ME-ICA, the data is best post-processed in order to remove spatially diffuse noise with a method such as aCompCor. Our findings indicate that ME-ICA combined with aCompCor and ICA-AROMA are highly effective denoising approaches for multi-echo data acquired at 7T. ME-ICA combined with aCompCor potentially preserves more signal-of-interest as compared to ICA-AROMA. Highlights- ME-ICA and ICA-AROMA provide effective denoising for multi-echo 7T fMRI data - High tSNR can be achieved in the brainstem with a multi-echo acquisition at 7T - After ME-ICA, the data is best post-processed to correct for spatially diffuse noise
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 15
- FWCI
- 2.47
- Field percentile
- top 11%
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Evaluating the efficacy of multi-echo ICA denoising on model-based fMRI
Adam Steel, Brenda D. Garcia, … Caroline Elizabeth Robertson·NeuroImagePeer-reviewed·Oct 31, 2022
- Denoising task-correlated head motion from motor-task fMRI data with multi-echo ICA
Neha Reddy, Kristina M. Zvolanek, … Molly G. Bright·Imaging NeurosciencePeer-reviewed·Dec 7, 2023
- Lowering the Thermal Noise Barrier in Functional Brain Mapping with Magnetic Resonance Imaging
Luca Vizioli, Steen Moeller, … Kǎmil Uǧurbil·Nature CommunicationsPeer-reviewed·Aug 30, 2021
- An Evaluation of the Efficacy of Single-Echo and Multi-Echo fMRI Denoising Strategies
Toby Constable, Jeggan Tiego, … Alex Fornito·Network NeurosciencePeer-reviewed·Jan 1, 2026
- Optimising 7T-fMRI for imaging regions of magnetic susceptibility
Saskia L Frisby, Marta Correia, … Ajay D. Halai·Human Brain MappingPeer-reviewed·Aug 1, 2026
- Robust-tedana: An automated denoising pipeline for multi-echo fMRI data
Bahman Tahayori, Robert Elton Smith, … David F. Abbott·bioRxiv·Jun 16, 2025