Sign in
Pharmacology & ToxicologybioRxiv
Preprint

Costing ‘the’ MTD … in 2-D

David C. NorrisiD

Abstract

BackgroundI have previously evaluated the efficiency of one-size-fits-all dosing for single agents in oncology (Norris 2017b). By means of a generic argument based on an Emax-type dose-response model, I showed that one-size-fits-all dosing may roughly halve a drugs value to society. Since much of the past decades innovation in oncology dose-finding methodology has involved the development of special methods for combination therapies, a generalization of my earlier investigations to combination dosing seems called-for.\n\nMethodsFundamental to my earlier work was the premise that optimal dose is a characteristic of each individual patient, distributed across the population like any other physiologic characteristic such as height. I generalize that principle here to the 2-dimensional setting of combination dosing with drugs A and B, using a copula to build a bivariate joint distribution of (MTDi,A, MTDi,B) from single-agent marginal densities of MTDi,A and MTDi,B, and interpolating toxicity isocontours in the (a, b)-plane between the respective monotherapy intercepts. Within this framework, three distinct notional toxicities are elaborated: one specific to drug A, a second specific to drug B, and a third nonspecific toxicity clinically attributable to either drug. The dose-response model of (Norris 2017b) is also generalized to this 2-D scenario, with the addition of an interaction term to provide for a complementary effect from combination dosing. A population of 1,000 patients is simulated, and used as a basis to evaluate population-level efficacy of two pragmatic dose-finding designs: a dose-titration method that maximizes dose-intensity subject to tolerability, and the well-known POCRM method for 1-size-fits-all combination-dose finding. Hypothetical oracular methods are also evaluated, to define theoretical upper limits of performance for individualized and 1-size-fits-all dosing respectively.\n\nResultsIn our simulation, pragmatic titration attains 89% efficiency relative to theoretically optimal individualized dosing, whereas POCRM attains only 55% efficiency. The passage from oracular individualized dosing to oracular 1-size-fits-all dosing incurs an efficiency loss of 33%, while the parallel passage (within the pragmatic realm) from titration to POCRM incurs a loss of 38%.\n\nConclusionsIn light of the 33% figure above, the greater part of POCRMs 38% efficiency loss relative to titration appears attributable to POCRMs 1-size-fits-all nature, rather than to any pragmatic difficulties it confronts. Thus, appeals to pragmatic considerations would seem neither to justify the decision to use 1-size-fits-all dose-finding designs, nor to excuse their inefficiencies

PDFDOI

02 /Specification & Classification

Click any tag to browse matching papers

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.