bioRxivNeurosciencePreprint
Microvascular Specificity of Spin Echo BOLD fMRI: Impact of EPI Echo Train Length
Tanya W.P. van Horen, Jeroen C.W. SieroiD, Alex A. BhogaliD, Natalia PetridouiD, Mario Gilberto Báez‐YáñeziD
Abstract
A spatially specific fMRI acquisition requires specificity to the microvasculature that serves active neuronal sites. Macrovascular contributions will reduce the microvascular specificity but can be reduced by using spin echo (SE) sequences that use a {pi} pulse to refocus static field inhomogeneities near large veins. The microvascular specificity of a SE-echo planar imaging (SE-EPI) scan depends on the echo train length (ETL)-duration, but the dependence is not well-characterized in humans at 7T. To determine how microvascular-specific SE-EPI BOLD is in humans at 7T, we developed a Monte Carlo voxel model that computes the signal of a proton ensemble residing in a vasculature subjected to a SE-EPI pulse sequence. We characterized the ETL-duration dependence of the microvascular specificity by simulating the BOLD signal as a function of ETL, the range adhering to experimentally realistic readouts. We performed a validation experiment for our simulation observations, in which we acquired a set of SE-EPI BOLD time series with varying ETL during a hyperoxic gas challenge. Both our simulations and measurements show an increase in macrovascular contamination as a function of ETL, with an increase of 30% according to our simulation and 60% according to our validation experiment between the shortest and longest ETL durations (23.1 - 49.7 ms). We conclude that the microvascular specificity decreases heavily with increasing ETL-durations. We recommend reducing the ETL-duration as much as possible to minimize macrovascular contamination in SE-EPI BOLD experiments. We additionally recommend scanning at high resolutions to minimize partial volume effects with CSF. CSF voxels show a large BOLD response, which can be attributed to both the presence of large veins (high blood volume) and molecular oxygen-induced T1-shortening (significant in a hyperoxia experiment). The magnified BOLD signal in a GM-CSF partial volume voxel reduces the desired microvascular specificity and, therefore, will hinder the interpretation of functional MRI activation patterns.
- organism: human
- assay: imaging
- research focus: benchmarking
- approach: statistical model
- approach: simulation
- Citations
- 6
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Simultaneous pure T2 and varying T2'-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses
Fuyixue Wang, Zijing Dong, … Kawin Setsompop·NeuroImagePeer-reviewed·Oct 14, 2021
- On the influence of the vascular architecture on Gradient Echo and Spin Echo BOLD fMRI signals across cortical depth: a simulation approach based on realistic 3D vascular networks
Mario Gilberto Báez‐Yáñez, Jeroen C.W. Siero, … Natalia Petridou·bioRxiv·May 30, 2024
- Macrovascular contributions to resting-state fMRI signals: A comparison between EPI and bSSFP at 9.4 Tesla
D. Ramadan, Sebastian Mueller, … J Bause·Imaging NeurosciencePeer-reviewed·Dec 18, 2024
- Spatial specificity of the functional gradient echo and spin echo BOLD signal across cortical depth at 7 T
Daniel Haenelt, Robert Trampel, … Nikolaus Weiskopf·bioRxiv·Jul 28, 2025
- The many layers of BOLD. On the contribution of different vascular compartments to laminar fMRI.
Wouter Schellekens, Alex A. Bhogal, … Natalia Petridou·bioRxiv·Oct 21, 2021
- Characterisation of laminar and vascular spatiotemporal dynamics of CBV and BOLD signals using VASO and ME-GRE at 7T in humans
Sebastian Dresbach, Laurentius Huber, … Rainer Goebel·Imaging NeurosciencePeer-reviewed·Jan 1, 2024