Imaging NeuroscienceNeurosciencePeer-reviewed journal article
Macrovascular contributions to resting-state fMRI signals: A comparison between EPI and bSSFP at 9.4 Tesla
D. RamadaniD, Sebastian MuelleriD, Rüdiger StirnbergiD, Dario BoschiD, Philipp EhsesiD, Klaus ScheffleriD, J BauseiD
Abstract
The draining-vein bias of T2*-weighted sequences, like gradient echo echo-planar imaging (GRE-EPI), can limit the spatial specificity of functional MRI (fMRI). The underlying extravascular signal changes increase with field strength (B0) and the perpendicularity of draining veins to the main axis of B0, and are therefore particularly problematic at ultra-high field (UHF). In contrast, simulations showed that T2-weighted sequences are less affected by the draining-vein bias, depending on the amount of rephasing of extravascular signal. As large pial veins on the cortical surface follow the cortical folding tightly, their orientation can be approximated by the cortical orientation to [Formula]. In our work, we compare the influence of the cortical orientation to [Formula] on the resting-state fMRI signal of three sequences aiming to understand their macrovascular contribution. While 2D GRE-EPI and 3D GRE-EPI (both T2*-weighted) showed a high dependence on the cortical orientation to [Formula], especially on the cortical surface, this was not the case for 3D balanced steady-state free precession (bSSFP) (T2/T1-weighted). Here, a slight increase of orientation dependence was shown in depths closest to WM. And while orientation dependence decreased with increased distance to the veins for both EPI sequences, no change in orientation dependence was observed in bSSFP. This indicates the low macrovascular contribution to the bSSFP signal, making it a promising sequence for layer fMRI at UHF.
- Citations
- 4
- FWCI
- 1.02
- Field percentile
- top 26%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Spatial specificity of the functional gradient echo and spin echo BOLD signal across cortical depth at 7 T
Daniel Haenelt, Robert Trampel, … Nikolaus Weiskopf·bioRxiv·Jul 28, 2025
- Microvascular Specificity of Spin Echo BOLD fMRI: Impact of EPI Echo Train Length
Tanya W.P. van Horen, Jeroen C.W. Siero, … Mario Gilberto Báez‐Yáñez·bioRxiv·Sep 15, 2023
- Simultaneous pure T2 and varying T2'-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses
Fuyixue Wang, Zijing Dong, … Kawin Setsompop·NeuroImagePeer-reviewed·Oct 14, 2021
- Benchmarking GE-BOLD, SE-BOLD, and SS-SI-VASO sequences for depth-dependent separation of feedforward and feedback signals in high-field MRI
Polina Iamshchinina, Daniel Haenelt, … Radoslaw Martin Cichy·bioRxiv·Dec 10, 2021
- A critical assessment of data quality and venous effects in ultra-high-resolution fMRI
Kendrick Kay, Keith Wakefield Jamison, … Kǎmil Uǧurbil·NeuroImagePeer-reviewed·Feb 5, 2019
- On the influence of the vascular architecture on Gradient Echo and Spin Echo BOLD fMRI signals across cortical depth: a simulation approach based on realistic 3D vascular networks
Mario Gilberto Báez‐Yáñez, Jeroen C.W. Siero, … Natalia Petridou·bioRxiv·May 30, 2024